Oscillatory control of sample dispersion in a continuous flow system

被引:1
作者
Bruno, H [1 ]
Andrade, F [1 ]
Iñón, F [1 ]
Tudino, M [1 ]
Troccolli, O [1 ]
机构
[1] Fac Ciencias Exactas & Nat Buenos Aires, Lab Anal Trazas, INQUIMAE, RA-1428 Buenos Aires, DF, Argentina
关键词
D O I
10.1039/b008157o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new strategy for the instrumental control of sample dispersion in continuous flow systems is presented. The method is based on shaking a loosely held straight reactor while the sample travels through the flow injection manifold. This external disturbance yields a sample transport more similar to the plug flow type because of the changes promoted on the flow pattern. Up to a three-fold increase in peak height, a comparable reduction in peak width and a more Gaussian peak profile are observed when the signals obtained with the shaken reactor are compared with those obtained with the same reactor but static. Improvements in the analytical performance as a function of different operational variables are shown for systems with or without a chemical reaction. Analytical implications and possible uses are discussed since this strategy allows the control of dispersion by simply selecting the frequency and amplitude of oscillation.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 17 条
[1]   Integrated conductimetric detection:: mass distribution in a dynamic sample zone inside a flow injection manifold [J].
Andrade, FJ ;
Iñon, FA ;
Tudino, MB ;
Troccoli, OE .
ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) :99-106
[2]   POTENTIOMETRIC DETECTORS FOR THE DETERMINATION OF ACIDITY BY DISCONTINUOUS FLOW-ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
OCONNELL, GR ;
PETTY, JD ;
SCOLLARY, GR .
ELECTROANALYSIS, 1992, 4 (08) :805-810
[3]   COMPARISON OF THE MAXIMUM SENSITIVITY OF DIFFERENT FLOW-INJECTION MANIFOLD CONFIGURATIONS - ALTERNATING VARIABLE SEARCH OPTIMIZATION OF THE IRON(II)/1,10-PHENANTHROLINE SYSTEM [J].
CHALK, SJ ;
TYSON, JF .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :660-666
[4]   EXPLOITING STOPPED-FLOW INJECTION METHODS FOR QUANTITATIVE CHEMICAL-ASSAYS [J].
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :11-21
[5]   FLOW-REVERSAL FLOW-INJECTION ANALYSIS - ENHANCEMENT OF FLOW-INJECTION TITRATIONS [J].
CLARK, GD ;
ZABLE, J ;
RUZICKA, J ;
CHRISTIAN, GD .
TALANTA, 1991, 38 (02) :119-124
[6]  
CURTIS MA, 1988, LC GC-MAG SEP SCI, V6, P158
[7]  
HULL RD, 1992, ANAL CHIM ACTA, V267, P1
[8]   LOW-DISPERSION CONNECTING TUBES FOR LIQUID-CHROMATOGRAPHY SYSTEMS [J].
KATZ, ED ;
SCOTT, RPW .
JOURNAL OF CHROMATOGRAPHY, 1983, 268 (02) :169-175
[9]   MATHEMATICAL-MODELING OF FLOW-INJECTION SYSTEMS [J].
KOLEV, SD .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :36-66
[10]   AXIAL-DISPERSION IN COILED TUBULAR REACTORS - THE EFFECT OF CURVATURE AT LOW DEAN NUMBERS [J].
LECLERC, DF ;
SMITH, CJ ;
TOREN, EC .
ANALYTICA CHIMICA ACTA, 1987, 194 :109-117