Towards an independent brain-computer interface using steady state visual evoked potentials

被引:215
作者
Allison, Brendan. Z. [1 ]
McFarland, Dennis J. [2 ,3 ]
Schalk, Gerwin [2 ,3 ]
Zheng, Shi Dong [1 ]
Jackson, Melody Moore [4 ]
Wolpaw, Jonathan R. [2 ,3 ]
机构
[1] Georgia State Univ, Comp Informat Syst Dept, GSU BrainLab, Atlanta, GA 30303 USA
[2] New York State Dept Hlth, Wadsworth Ctr, Lab Nervous Syst Disorders, Albany, NY 12201 USA
[3] SUNY Albany, Albany, NY 12201 USA
[4] Georgia Inst Technol, Sch Interact Comp, Atlanta, GA 30308 USA
关键词
BCI; BMI; EEG; ALS; locked in syndrome; SSVEP; attention; dependent; assistive communication;
D O I
10.1016/j.clinph.2007.09.121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Brain-computer interface (BCI) systems using steady state visual evoked potentials (SSVEPs) have allowed healthy subjects to communicate. However, these systems may not work in severely disabled users because they may depend on gaze shifting. This study evaluates the hypothesis that overlapping stimuli can evoke changes in SSVEP activity sufficient to control a BCI. This would provide evidence that SSVEP BCIs could be used without shifting gaze. Methods: Subjects viewed a display containing two images that each oscillated at a different frequency. Different conditions used overlapping or non-overlapping images to explore dependence on gaze function. Subjects were asked to direct attention to one or the other of these images during each of 12 one-minute runs. Results: Half of the subjects produced differences in SSVEP activity elicited by overlapping stimuli that could support BCI control. In all remaining users, differences did exist at corresponding frequencies but were not strong enough to allow effective control. Conclusions: The data demonstrate that SSVEP differences sufficient for BCI control may be elicited by selective attention to one of two overlapping stimuli. Thus, some SSVEP-based BCI approaches may not depend on gaze control. The nature and extent of any BCI's dependence on muscle activity is a function of many factors, including the display, task, environment, and user. Significance: SSVEP BCIs might function in severely disabled users unable to reliably control gaze. Further research with these users is necessary to explore the optimal parameters of such a system and validate online performance in a home environment. (c) 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:399 / 408
页数:10
相关论文
共 46 条
  • [1] Brain-computer interface systems: progress and prospects
    Allison, Brendan Z.
    Wolpaw, Elizabeth Winter
    Wolpaw, Andjonothan R.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (04) : 463 - 474
  • [2] ERPs evoked by different matrix sizes: Implications for a brain computer interface (BCI) system
    Allison, BZ
    Pineda, JA
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) : 110 - 113
  • [3] ALLISON BZ, 2006, J COGNITIVE NEUROS S, V59, P127
  • [4] ALLISON BZ, 2003, P3 NOT P3 BETTER P30
  • [5] The effect of spatial frequency on chromatic and achromatic steady-state visual evoked potentials
    Arakawa, K
    Tobimatsu, S
    Tomoda, H
    Kira, J
    Kato, M
    [J]. CLINICAL NEUROPHYSIOLOGY, 1999, 110 (11) : 1959 - 1964
  • [6] Beverina F., 2003, PsychNology Journal, V1, P331
  • [7] The thought-translation device (TTD):: Neurobehavioral mechanisms and clinical outcome
    Birbaumer, N
    Hinterberger, T
    Kübler, A
    Neumann, N
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) : 120 - 123
  • [8] Rab27b is associated with fusiform vesicles and may be involved in targeting uroplakins to urothelial apical membranes
    Chen, YR
    Guo, XM
    Deng, FM
    Liang, FX
    Sun, WY
    Ren, MD
    Izumi, T
    Sabatini, DD
    Sun, TT
    Kreibich, G
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) : 14012 - 14017
  • [9] Design and implementation of a brain-computer interface with high transfer rates
    Cheng, M
    Gao, XR
    Gao, SG
    Xu, DF
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (10) : 1181 - 1186
  • [10] Cook A., 2002, ASSISTIVE TECHNOLOGI, V2nd