High performance liquid chromatographic determination of topiramate in human serum using UV detection

被引:39
作者
Bahrami, G [1 ]
Mirzaeei, S
Mohammadi, B
Kiani, A
机构
[1] Kermanshah Univ Med Sci, Med Sch, Med Biol Res Ctr, Kermanshah, Iran
[2] Kermanshah Univ Med Sci, Sch Pharm, Kermanshah, Iran
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 822卷 / 1-2期
关键词
reverse phase chromatography; HPLC; topiramate; UV detection;
D O I
10.1016/j.jchromb.2005.05.032
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05 M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 mu g/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992 (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:322 / 325
页数:4
相关论文
共 16 条
[1]
Sensitive analytical method for Topiramate in human serum by HPLC with pre-column fluorescent derivatization and its application in human pharmacokinetic studies [J].
Bahrami, G ;
Mirzaeei, S ;
Kiani, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :175-180
[2]
Comparison of topiramate concentrations in plasma and serum by fluorescence polarization immunoassay [J].
Berry, DJ ;
Patsalos, PN .
THERAPEUTIC DRUG MONITORING, 2000, 22 (04) :460-464
[3]
Analysis of topiramate and its metabolites in plasma and urine of healthy subjects and patients with epilepsy by use of a novel liquid chromatography-mass spectrometry assay [J].
Britzi, M ;
Soback, S ;
Isoherranen, N ;
Levy, RH ;
Perucca, E ;
Doose, DR ;
Maryanoff, BE ;
Bialer, M .
THERAPEUTIC DRUG MONITORING, 2003, 25 (03) :314-322
[4]
Plasma and urinary endothelin-1 in focal segmental glomerulosclerosis [J].
Chen, HC ;
Guh, JY ;
Chang, JM ;
Tsai, JC ;
Hwang, SJ ;
Lai, YH .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2001, 15 (02) :59-63
[5]
Chen S, 1999, RAPID COMMUN MASS SP, V13, P1980, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1980::AID-RCM741>3.0.CO
[6]
2-C
[7]
Liquid chromatography tandem mass spectrometry assay for topiramate analysis in plasma and cerebrospinal fluid: Validation and comparison with fluorescence-polarization immunoassay [J].
Christensen, J ;
Hojskov, CS ;
Poulsen, JH .
THERAPEUTIC DRUG MONITORING, 2002, 24 (05) :658-664
[8]
Simple and rapid liquid chromatographic-turbo ion spray mass spectrometric determination of topiramate in human plasma [J].
Contin, M ;
Riva, R ;
Albani, F ;
Baruzzi, A .
JOURNAL OF CHROMATOGRAPHY B, 2001, 761 (01) :133-137
[9]
AUTOMATED CAPILLARY GAS-CHROMATOGRAPHIC ASSAY USING FLAME IONIZATION DETECTION FOR THE DETERMINATION OF TOPIRAMATE IN PLASMA [J].
HOLLAND, ML ;
UETZ, JA ;
NG, KT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 :276-281
[10]
Topiramate - A review of its pharmacodynamic and pharmacokinetic properties and clinical efficacy in the management of epilepsy [J].
Langtry, HD ;
Gillis, JC ;
Davis, R .
DRUGS, 1997, 54 (05) :752-773