Measurements and Monte Carlo calculations to determine the absolute detector response of radiochromic film for brachytherapy dosimetry

被引:18
作者
Bohm, TD
Pearson, DW
Das, RK
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
关键词
Monte Carlo; MCNP; radiochromic film; dosimetry;
D O I
10.1118/1.1333412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
GafChromic (MD-55-2) radiochromic film has become increasingly popular fur medical applications and has proven to be useful for brachytherapy dosimetry. To measure the absolute dose near a brachytherapy source, the response of the proposed detector in the measurement conditions relative to the response of the detector in calibration conditions must be known. MD-55-2 radiochromic film has been exposed in four different photon beams, a 30 and 40 kVp tungsten anode x-ray beam, a 75 kVp orthovoltage therapy beam, and a Co-60 teletherapy beam to measure the relative detector response. These measurements were combined with coupled photon/electron Monte Carlo transport calculations to determine the absolute detector response. The Los Alamos National Laboratory Monte Carlo transport code MCNP4B2 was used. The measured relative response of this batch of MD-55-2 film varies from 8.79 mOD/Gy, measured for the Co-60 beam, by as much as 42% for the low-energy x-ray beams. However, the absolute detector response varies from 4.32 mOD/Gy for the 60Co beam by, at most, only 6.3%. In this work we demonstrate that the absolute detector response of MD-55-2 radiochromic film is a constant and independent of beam quality. Further, this work shows that MCNP4B2 accurately simulates the energy response and geometry artifacts of the radiochromic film. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 18 条
[1]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[2]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[3]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[4]   HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED [J].
CHIUTSAO, ST ;
DELAZERDA, A ;
LIN, J ;
KIM, JH .
MEDICAL PHYSICS, 1994, 21 (05) :651-657
[5]   Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts [J].
Das, RK ;
Li, Z ;
Perera, H ;
Williamson, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06) :995-1006
[6]  
FEWELL TR, 1975, SPIE, V56, P9
[7]  
Halbleib J A, 1992, SAND911634 SAND NAT
[8]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[9]  
*LOS AL NAT LAB, 1997, DLC189 LOS AL NAT LA
[10]   Novel radiochromic films for clinical dosimetry [J].
McLaughlin, WL ;
Puhl, JM ;
AlSheikhly, M ;
Christou, CA ;
Miller, A ;
Kovacs, A ;
Wojnarovits, L ;
Lewis, DF .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :263-268