摘要
Diethylene glycol (DEG) is extensively used on offshore-as platforms to prevent the hydrate formation during the gas-water separation process and to inhibit corrosion events. This chemical might enter in the marine environment via the produced formation water (PEW) discharge. In this study, a new approach was applied to the investigation of the DEG content in PEW discharges and seawater samples from four gas installation platforms in the Adriatic Sea (Italy). The method includes an off-line solid-phase extraction/preconcentration technique, followed by a nanoscale flow injection/direct-electron ionization (EI) mass spectrometric analysis. Direct-EI is a novel and miniaturized interface for directly coupling a liquid chromatograph with an electron ionization mass spectrometer. The capability to acquire El spectra, and to operate in selected ion monitoring mode during actual sample analyses, allowed a precise quantification of DEG with a method limit of detection of 31 mu g/l. In addition, a careful evaluation of the matrix effect showed that, as opposed to electrospray ionization, the response of the Direct-EI interface was not affected by sample interferences. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:554 / 560
页数:7
相关论文
共 31 条
[1]  
[Anonymous], ENV XENOBIOTICS
[2]   Developmental toxicity study with diethylene glycol dosed by gavage to CD rats and CD-1 mice [J].
Ballantyne, B ;
Snellings, WA .
FOOD AND CHEMICAL TOXICOLOGY, 2005, 43 (11) :1637-1646
[3]   Improved extraction of glycol ethers from water by solid-phase micro extraction by carboxen polydimethylsiloxane-coated fiber [J].
Bensoam, J ;
Cicolella, A ;
Dujardin, R .
CHROMATOGRAPHIA, 1999, 50 (3-4) :155-159
[4]   GENERATION OF SPIT-FLOW MICRO-GRADIENTS FOR CAPILLARY HPLC [J].
BERLONI, A ;
CAPPIELLO, A ;
FAMIGLINI, G ;
PALMA, P .
CHROMATOGRAPHIA, 1994, 39 (5-6) :279-284
[5]  
BRENDEHAUG J, 1992, ENVIR SCI R, V46, P245
[6]   Electron ionization for LC/MS [J].
Cappiello, A ;
Famiglini, G ;
Palma, P .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :496A-503A
[7]   A simple approach for coupling liquid chromatography and electron ionization mass spectrometry [J].
Cappiello, A ;
Famiglini, G ;
Mangani, F ;
Palma, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (03) :265-273
[8]   New trends in the application of electron ionization to liquid chromatography-mass spectrometry interfacing [J].
Cappiello, A ;
Famiglini, G ;
Mangani, F ;
Palma, P .
MASS SPECTROMETRY REVIEWS, 2001, 20 (02) :88-104
[9]   LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices [J].
Choi, BK ;
Hercules, DM ;
Gusev, AI .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4) :370-377
[10]  
DRUGOV YS, 1995, J ANAL CHEM+, V50, P899