Early detection of human immunodeficiency virus infection using third- and fourth-generation screening assays

被引:39
作者
Ly, TD
Laperche, S
Couroucé, AM
机构
[1] Lab Claude Levy, F-94200 Ivry, France
[2] Inst Natl Transfus Sanguine, F-75739 Paris 15, France
关键词
D O I
10.1007/s10096-001-8057-0
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Early detection of infection with human immunodeficiency virus (HIV) is critical for clinical diagnosis and treatment of patients, as well as for ensuring the safety of blood transfusion products. Recently, a number of fourth-generation HIV screening assays have been developed that offer increased sensitivity over earlier tests by combining detection of anti-HIV antibodies with detection of the p24 viral antigen. Previously, six different HIV assays were compared against a broad range of 30 seroconversion panels. In the present study, three of the newer fourth-generation assays were tested together with three of the third-generation HIV antibody-only assays. This extensive analysis highlights (i) the importance of p24 antigen detection for early diagnosis, (ii) the improved sensitivity of fourth-generation assays over antibody-only tests, and (iii) the superior performance of the Vidas Duo assay, which allows reduction of the diagnostic window by up to 2 weeks. Finally, the results emphasize the detection limitations of the different assays and suggest improvements for future HIV screening assays.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 11 条
[1]   SCREENING OF SELECTED MALE BLOOD-DONORS FOR P24 ANTIGEN OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 [J].
BUSCH, MP ;
TAYLOR, PE ;
LENES, BA ;
KLEINMAN, SH ;
STUART, M ;
STEVENS, CE ;
TOMASULO, PA ;
ALLAIN, JP ;
HOLLINGSWORTH, CG ;
MOSLEY, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (19) :1308-1312
[2]   BLOOD-TRANSFUSION AND HUMAN IMMUNODEFICIENCY VIRUS (HIV) ANTIGEN [J].
COUROUCE, AM ;
BOUCHARDEAU, F ;
JULLIEN, AM ;
FAUCHER, V ;
LENTZY, M .
ANNALS OF INTERNAL MEDICINE, 1988, 108 (05) :771-772
[3]  
COUROUCE AM, 1994, SPECTRA BIOL, V94, P43
[4]   Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay [J].
Gürtler, L ;
Mühlbacher, A ;
Michl, U ;
Hofmann, H ;
Paggi, GG ;
Bossi, V ;
Thorstensson, R ;
Villaescusa, RG ;
Eiras, A ;
Hernandez, JM ;
Melchior, W ;
Donie, F ;
Weber, B .
JOURNAL OF VIROLOGICAL METHODS, 1998, 75 (01) :27-38
[5]  
KESSLER HA, 1987, JAMA-J AM MED ASSOC, V258, P1196
[6]  
Ly TD, 2000, J CLIN MICROBIOL, V38, P2459
[7]  
SIEGEL S, 1998, NONPARAMETRIC STAT B, P174
[8]   Evaluation of 14 commercial HIV-1/HIV-2 antibody assays using serum panels of different geographical origin and clinical stage including a unique seroconversion panel [J].
Thorstensson, R ;
Andersson, S ;
Lindbäck, S ;
Dias, F ;
Mhalu, F ;
Gaines, H ;
Biberfeld, G .
JOURNAL OF VIROLOGICAL METHODS, 1998, 70 (02) :139-151
[9]   Strongly enhanced sensitivity of a direct anti-HIV-1/-2 assay in seroconversion by incorporation of HIV p24 ag detection:: a new generation vironostika HIV Uni-Form II [J].
van Binsbergen, J ;
Keur, W ;
Siebelink, A ;
van de Graaf, M ;
Jacobs, A ;
de Rijk, D ;
Nijholt, L ;
Toonen, J ;
Gürtler, LG .
JOURNAL OF VIROLOGICAL METHODS, 1998, 76 (1-2) :59-71
[10]   Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays [J].
Weber, B ;
Fall, EHM ;
Berger, A ;
Doerr, HW .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (08) :2235-2239