Retention of neutral solutes in capillary electrochromatography

被引:14
作者
Djordjevic, NM [1 ]
Fowler, PWJ [1 ]
Houdiere, F [1 ]
Lerch, G [1 ]
机构
[1] Novartis Pharma Ltd, Pharma Discovery, CH-4002 Basel, Switzerland
关键词
D O I
10.1080/10826079808006621
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The retention mechanisms of neutral solutes were compared between electrically driven chromatography and pressure driven chromatography. The entropies of solute transfer from a mobile phase to a stationary phase were more negative in electrically driven chromatography than in pressure driven liquid chromatography. These differences can be attributed, in part, to the generation of heat which occurs during electro-driven chromatography and which causes significant differences between the set and the actual column temperature. Retention factors in electrochromatography are affected significantly by changes in electric field strength. These variations can be minimized by performing the experiments at elevated column temperatures. For example, when the column temperature was increased from 293 K to 333 K,the RSD for pentachlorobenzene was lowered from 7.3 % to 4.3 %. In addition the analysis time was shortened by approximately 45 %. Due to the critical effect of temperature on separation in electrochromatography, it is imperative that the column temperature be kept constant and measured accurately.
引用
收藏
页码:2219 / 2232
页数:14
相关论文
共 22 条
[1]   ELECTROCHROMATOGRAPHY - A PRELIMINARY-STUDY OF THE EFFECT OF APPLIED POTENTIAL ON A CARBONACEOUS CHROMATOGRAPHIC COLUMN [J].
ANTRIM, RF ;
SCHERRER, RA ;
YACYNYCH, AM .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :283-286
[2]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[3]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[4]  
Dittmann MM, 1995, LC GC-MAG SEP SCI, V13, P800
[5]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[6]  
GROSSMAN PD, 1992, CAPILLARY ELECTROPHO, P12
[7]   TERMINOLOGY AND NOMENCLATURE IN CAPILLARY ELECTROSEPARATION SYSTEMS [J].
KNOX, JH .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :3-13
[8]   MINIATURIZATION IN PRESSURE AND ELECTROENDOSMOTICALLY DRIVEN LIQUID-CHROMATOGRAPHY - SOME THEORETICAL CONSIDERATIONS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1987, 24 :135-143
[9]   ELECTROCHROMATOGRAPHY IN PACKED TUBES USING 1.5 TO 50 MU-M SILICA-GELS AND ODS BONDED SILICA-GELS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1991, 32 (7-8) :317-328
[10]   THERMAL EFFECTS AND BAND SPREADING IN CAPILLARY ELECTRO-SEPARATION [J].
KNOX, JH .
CHROMATOGRAPHIA, 1988, 26 :329-337