Emergent technologies for 3-dimensional image-guided radiation delivery

被引:118
作者
Jaffray, DA [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Radiat Oncol, Princess Margaret Hosp,Radiat Med Program, Toronto, ON M5G 2M9, Canada
基金
美国国家卫生研究院;
关键词
D O I
10.1016/j.semradonc.2005.01.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiation therapy targeting is being refined to formally accommodate location of gross disease, microscopic extension, and geometric uncertainties in the delivery process. This formalization allows the disciplines in radiation oncology practice to work collaboratively to assure target coverage while attempting to minimize toxicity in adjacent normal structures. There is a growing expectation that the precise and accurate placement of radiation dose is well in hand. The development of volumetric imaging systems integrated with the medical linear accelerator for the specific purpose of guiding therapy will permit localization and targeting of soft-tissue structures at the time of treatment. In this review, the context for development of image-guided radiation therapy is discussed, and the growing expectation of volumetric guidance is portrayed through the various technologies currently being explored in the radiation therapy community. © 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:208 / 216
页数:9
相关论文
共 58 条
[1]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[2]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[3]  
Bissonnette JP, 2004, MED PHYS, V31, P1860
[4]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[5]   RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS [J].
BRAHME, A ;
LIND, B ;
NAFSTADIUS, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :95-101
[6]  
Chen J, 2004, INT J RADIAT ONCOL, V60, pS588
[7]  
Cheng Chee-Wai, 2003, Am J Clin Oncol, V26, pe28, DOI 10.1097/00000421-200306000-00027
[8]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[9]   Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system [J].
Court, L ;
Rosen, I ;
Mohan, R ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (06) :1198-1210
[10]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619