Collision induced ion ejection in an FTICR trapped-ion cell

被引:7
作者
Arkin, CR [1 ]
Laude, DA [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem A5300, Austin, TX 78712 USA
关键词
D O I
10.1016/j.jasms.2004.12.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A collision algorithm was used with SimIon to evaluate collision-mediated ion ejection mechanisms in the ICR MS experiment. These mechanisms were characterized based on kinetic energy, ion mass, applied trapping potential, and collision gas mass. It was found that there are three collision-based energy regimes for ion loss from a trapped-ion cell. The first region is characterized by low initial cyclotron kinetic energy, a radial ejection mode, and a very high collision ratio (>100 collisions per ejection). The second region is characterized by a medium to high initial cyclotron kinetic energy leading to axial ejection at low collision ratio (1 to 10 collisions per ejection). The third region is characterized by a high initial cyclotron kinetic energy, a radial ejection mode, and a collision ratio of unity. It was also determined that there is a radial cyclotron mode limit, approximately 40% of the cell radius, after which an ion is ejected after a single collision. This has important consequences on the damping of the FTICR signal, various cooling techniques, ion activation techniques, and the remeasurement experiment. (J Am Soc Mass Spectrom 2005, 16, 422-430) (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:422 / 430
页数:9
相关论文
共 21 条
[1]  
ANDERSON SA, 1996, THESIS U TEXAS AUSTI
[2]  
ARKIN CR, 2000, THESIS U TEXAS AUSTI
[3]   THEORY OF COLLISION-BROADENED ION CYCLOTRON RESONANCE SPECTRA [J].
BEAUCHAMP, JL .
JOURNAL OF CHEMICAL PHYSICS, 1967, 46 (04) :1231-+
[4]   RADIAL ION-TRANSPORT DUE TO RESISTIVE-WALL DESTABILIZATION IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (2-3) :255-268
[5]  
COMISAROW MB, 1982, LECT NOTES CHEM, P484
[6]  
DAHL AD, 1995, P 4O ASMS C MASS SPE, P717
[7]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[8]  
GENTLE JE, 1998, RANDOM NUMBER GENERA, P96
[9]   CAN FOURIER-TRANSFORM MASS-SPECTRAL RESOLUTION BE IMPROVED BY DETECTION AT HARMONIC MULTIPLES OF THE FUNDAMENTAL ION-CYCLOTRON ORBITAL FREQUENCY [J].
GROSSHANS, PB ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 107 (01) :49-81
[10]   QUADRUPOLAR AXIALIZATION FOR IMPROVED CONTROL OF ELECTROSPRAYED PROTEINS IN FTICR MASS-SPECTROMETRY [J].
HENDRICKSON, CL ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1717-1721