QUADRUPOLAR AXIALIZATION FOR IMPROVED CONTROL OF ELECTROSPRAYED PROTEINS IN FTICR MASS-SPECTROMETRY

被引:21
作者
HENDRICKSON, CL
LAUDE, DA
机构
[1] Department of Chemistry and Biochemistry, The University of Texas at Austin, Texas, Austin
关键词
D O I
10.1021/ac00106a011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quadrupolar axialization is implemented on a high-held electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer, The method is utilized to perform highly efficient remeasurement of small proteins which were not previously amenable to the remeasurement process. For example, 100 consecutive remeasurements of the same population of melittin ions (MW 2845) yield the theoretical 10-fold improvement in signal-to-noise ratio compared to the first measurement. The efficiency of the cooling process is evaluated as a function of excitation radius and ion mass, and the results are compared to instrumental performance prior to the implementation of quadrupolar axialization. The maximum achievable excitation radius for efficient remeasurement is increased from 18% to 52% of the trapped ion cell radius. The application of quadrupolar axialization during the electrospray ion accumulation event results in a factor of 3 improvement in sensitivity when acquiring bovine insulin (MW 5734) spectra under high-resolution conditions. The mass selectivity of the technique is used to isolate a single charge state of horse myoglobin (MW 16 951).
引用
收藏
页码:1717 / 1721
页数:5
相关论文
共 36 条
[1]  
ASOMOTO B, 1991, ANAL APPLICATIONS FT
[2]   MASS MEASUREMENTS OF VERY HIGH-ACCURACY BY TIME-OF-FLIGHT ION-CYCLOTRON RESONANCE OF IONS INJECTED INTO A PENNING TRAP [J].
BECKER, S ;
BOLLEN, G ;
KERN, F ;
KLUGE, HJ ;
MOORE, RB ;
SAVARD, G ;
SCHWEIKHARD, L ;
STOLZENBERG, H .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 99 (1-2) :53-77
[3]   RADIAL ION-TRANSPORT DUE TO RESISTIVE-WALL DESTABILIZATION IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (2-3) :255-268
[4]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[5]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[6]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[7]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[8]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[9]   SELECTED-ION ACCUMULATION FROM AN EXTERNAL ELECTROSPRAY-IONIZATION SOURCE WITH A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
BRUCE, JE ;
ANDERSON, GA ;
HOFSTADLER, SA ;
VANORDEN, SL ;
SHERMAN, MS ;
ROCKWOOD, AL ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :914-919
[10]   CELL GEOMETRY CONSIDERATIONS FOR THE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY REMEASUREMENT EXPERIMENT [J].
CAMPBELL, VL ;
GUAN, ZQ ;
VARTANIAN, VH ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :420-425