QUADRUPOLAR AXIALIZATION FOR IMPROVED CONTROL OF ELECTROSPRAYED PROTEINS IN FTICR MASS-SPECTROMETRY

被引:21
作者
HENDRICKSON, CL
LAUDE, DA
机构
[1] Department of Chemistry and Biochemistry, The University of Texas at Austin, Texas, Austin
关键词
D O I
10.1021/ac00106a011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quadrupolar axialization is implemented on a high-held electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer, The method is utilized to perform highly efficient remeasurement of small proteins which were not previously amenable to the remeasurement process. For example, 100 consecutive remeasurements of the same population of melittin ions (MW 2845) yield the theoretical 10-fold improvement in signal-to-noise ratio compared to the first measurement. The efficiency of the cooling process is evaluated as a function of excitation radius and ion mass, and the results are compared to instrumental performance prior to the implementation of quadrupolar axialization. The maximum achievable excitation radius for efficient remeasurement is increased from 18% to 52% of the trapped ion cell radius. The application of quadrupolar axialization during the electrospray ion accumulation event results in a factor of 3 improvement in sensitivity when acquiring bovine insulin (MW 5734) spectra under high-resolution conditions. The mass selectivity of the technique is used to isolate a single charge state of horse myoglobin (MW 16 951).
引用
收藏
页码:1717 / 1721
页数:5
相关论文
共 36 条
[11]   SELECTIVE GENERATION OF CHARGE-DEPENDENT - INDEPENDENT ION ENERGY-DISTRIBUTIONS FROM A HEATED CAPILLARY ELECTROSPRAY SOURCE [J].
CAMPBELL, VL ;
GUAN, ZQ ;
LAUDE, DA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :221-229
[12]   SINGLE-ION CYCLOTRON-RESONANCE MEASUREMENT OF M(CO+) M(N2+) [J].
CORNELL, EA ;
WEISSKOFF, RM ;
BOYCE, KR ;
FLANAGAN, RW ;
LAFYATIS, GP ;
PRITCHARD, DE .
PHYSICAL REVIEW LETTERS, 1989, 63 (16) :1674-1677
[13]  
FRANCL TJ, 1991, INT J MASS SPECTROM, V108, P255
[14]   MULTIPLY PULSED COLLISION GAS FOR ION AXIALIZATION IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
GUAN, SG ;
MARSHALL, AG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (09) :857-860
[15]   BLOCH EQUATIONS APPLIED TO ION-CYCLOTRON RESONANCE SPECTROSCOPY - BROAD-BAND INTERCONVERSION BETWEEN MAGNETRON AND CYCLOTRON MOTION FOR ION AXIALIZATION [J].
GUAN, SH ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (06) :4486-4493
[16]   BROAD-BAND AXIALIZATION IN AN ION-CYCLOTRON RESONANCE ION-TRAP [J].
GUAN, SH ;
WAHL, MC ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1994, 100 (09) :6137-6140
[17]   ENHANCED MASS RESOLVING POWER, SENSITIVITY, AND SELECTIVITY IN LASER-DESORPTION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY BY ION AXIALIZATION AND COOLING [J].
GUAN, SH ;
WAHL, MC ;
WOOD, TD ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1753-1757
[18]   MS/MS WITH HIGH DETECTION EFFICIENCY AND MASS RESOLVING POWER FOR PRODUCT IONS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
GUAN, SH ;
MARSHALL, AG ;
WAHL, MC .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :1363-1367
[19]  
GUAN Z, UNPUB REV SCI INSTRU
[20]   REMEASUREMENT OF ELECTROSPRAYED PROTEINS IN THE TRAPPED ION CELL OF A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
GUAN, ZQ ;
HOFSTADLER, SA ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1588-1593