Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions

被引:12
作者
Gregory, CL
Nullens, HA
Gijbels, RH [1 ]
Van Espen, PJ
Geuens, I
De Keyzer, R
机构
[1] Univ Antwerp, Dept Chem, B-2610 Wilrijk, Belgium
[2] Agfa Gevaert NV, B-2640 Mortsel, Belgium
关键词
D O I
10.1021/ac9710644
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated particle analysis routine is implemented on an electron microprobe for analyzing the chemical composition and projective area of populations of individual silver halide microcrystals. An LN2 cryostage is used to prevent material degradation due to reaction with the impinging electron beam. The background in the EDX spectra is lowered by depositing the microcrystals on a carbon-coated copper grid, mounted in a transmission holder. The IL-alpha/AgL-alpha net X-ray intensity ratio, obtained from a spectrum-fitting algorithm, is used to determine the crystal composition by means of a standard-based calibration curve. The uncertainty on the concentration measurement of individual microcrystals is calculated using the uncertainties on the net X-ray counts and the uncertainties on the calibration curve. The area measurement is optimized by introducing a gray value histogram correction on each individual measurement. Overlapping microcrystals are scrapped from the analysis by defining a maximum shape factor, against which the shape factor of the microcrystal is tested. To minimize problems with drift of the cryostage, spectrum acquisition is carried out immediately after a single microcrystal has been located, based on the backscattered electron image. Several applications are discussed.
引用
收藏
页码:2551 / 2559
页数:9
相关论文
共 32 条
[1]  
BLACK DL, 1994, J IMAGING SCI TECHN, V38, P10
[2]  
BROADHEAD P, 1977, THEORY PHOTOGRAPHIC, pCH1
[3]  
CLAES FH, 1968, PHOTOGR SCI ENG, V12, P207
[4]  
GAO XL, 1989, J IMAGING SCI, V33, P87
[5]  
GEUENS I, 1992, J IMAGING SCI TECHN, V36, P534
[6]  
GEUENS I, 1994, P ICPS 94, P27
[7]   CHARACTERIZATION OF CRYSTAL DEFECTS IN MIXED TABULAR SILVER-HALIDE GRAINS BY CONVENTIONAL TRANSMISSION ELECTRON-MICROSCOPY AND X-RAY-DIFFRACTOMETRY [J].
GOESSENS, C ;
SCHRYVERS, D ;
VANLANDUYT, J ;
AMELINCKX, S ;
VERBEECK, A ;
DEKEYZER, R .
JOURNAL OF CRYSTAL GROWTH, 1991, 110 (04) :930-941
[8]   EFFICIENCY OF PRODUCTION OF CHARACTERISTIC X-RADIATION IN THICK TARGETS OF A PURE ELEMENT [J].
GREEN, M ;
COSSLETT, VE .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1961, 78 (505) :1206-&
[9]   Evaluation of characterization methods for thin sections of silver halide microcrystals by analytical electron microscopy [J].
Gregory, C ;
Gijbels, R ;
Jacob, W ;
Geuens, I ;
VanRoost, C ;
DeKeyzer, A .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 188 :79-87
[10]  
HAEFKE H, 1991, J IMAGING SCI, V35, P290