A computer model of the position of the combined component in the prevention of impingement in total hip replacement

被引:31
作者
Barsoum, W. K. [1 ]
Patterson, R. W. [1 ]
Higuera, C. [1 ]
Klika, A. K. [1 ]
Krebs, V. E. [1 ]
Molloy, R. [1 ]
机构
[1] Cleveland Clin, Dept Orthopaed, Cleveland, OH 44795 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2007年 / 89B卷 / 06期
关键词
D O I
10.1302/0301-620X.89B6.18644
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three- dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement. We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability.
引用
收藏
页码:839 / 845
页数:7
相关论文
共 48 条
[1]
Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[2]
The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[3]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[4]
Bernsmann K, 2001, Z ORTHOP GRENZGEB, V139, P512
[5]
BIERDERMANN R, 2005, J BONE JOINT SURG BR, V87, P762
[6]
Cameron H. U., 1992, TECHNIQUE TOTAL HIP
[7]
Charnley J., 1979, LOW FRICTION ARTHROP
[8]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[9]
CROWNINSHIELD RD, 2004, CLIN ORTHOP RELAT R, V429, P102
[10]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321