A New Method of Registration in Navigated Hip Arthroplasty Without the Need to Register the Anterior Pelvic Plane

被引:18
作者
Davis, Edward T. [1 ,2 ]
Schubert, Mario [3 ]
Wegner, Melanie [3 ]
Haimerl, Martin [3 ]
机构
[1] Royal Orthopaed Hosp NHS Fdn Trust, Birmingham, W Midlands, England
[2] Dudley Grp NHS Fdn Trust, Dudley, W Midlands, England
[3] Brainlab AG, R&D Surg, Feldkirchen, Germany
关键词
computer navigation; computer assisted surgery; total hip arthroplasty; acetabular component orientation; component position; ACETABULAR COMPONENT ORIENTATION; CUP PLACEMENT; POLYETHYLENE WEAR; IMAGELESS NAVIGATION; ACCURACY; DISLOCATION; POSITION; RISK;
D O I
10.1016/j.arth.2014.08.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
A prospective clinical study of 50 patients was conducted to validate a new method of imageless computer navigated hip arthroplasty. The new method enables the surgeon to acquire all registration points with the patient positioned and draped in lateral decubitus position. The final component orientation was measured from post operative CT scans The mean error in component position was -1.1 degrees (SD 3.1 degrees) for inclination and 0.9 degrees (SD 4.3 degrees) for anteversion. This compared favourably with the error of -1.8 degrees (SD 1.8 degrees) for inclination and -4.8 degrees (SD 2.7 degrees) for anteversion when using the traditional APP registration. Results show that one can expect the acetabular component to be within a sate zone of +/- 10 degrees in 99.8% for inclination and 97.7% for anteversion when using the new lateral registration method. Level of Evidence Level II, Prognostic study. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 30 条
[1]
Socket Position Determines Hip Resurfacing 10-Year Survivorship [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. ;
Johnson, Alicia J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) :3127-3133
[2]
The Combined Anteversion Technique for Acetabular Component Anteversion [J].
Amuwa, Christopher ;
Dorr, Lawrence D. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :1068-1070
[3]
Berry D J, 2001, Instr Course Lect, V50, P265
[4]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[5]
Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[6]
The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[7]
Davis ET, 2012, CAOS INT
[8]
De Haan R, 2009, J BONE JOINT SURG BR, V91B, P700
[9]
Three-dimensional polyethylene wear of a press-fit titanium prosthesis - Factors influencing generation of polyethylene debris [J].
Devane, PA ;
Horne, JG ;
Martin, K ;
Coldham, G ;
Krause, B .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :256-266
[10]
Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position [J].
Dorr, Lawrence A. ;
Malik, Aamer ;
Wan, Zhinian ;
Long, William T. ;
Harris, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :92-99