Utility of global positioning system to measure active transport in urban areas

被引:39
作者
Duncan, Mitch J.
Mummery, W. Kerry
Dascombe, Ben J.
机构
[1] Univ Cent Queensland, Ctr Social Sci Res, Rockhampton, Qld 4701, Australia
[2] Univ Cent Queensland, Dept Hlth & Human Performance, Rockhampton, Qld 4701, Australia
关键词
active transportation; GPS; reliability; travel distance;
D O I
10.1249/mss.0b013e31811ff31e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this study was to determine test-retest reliability of global positioning system (GPS) units for measuring distance traveled when walking and cycling (AT), and to determine whether GPS unit placement influences accuracy. Methods: Participants (N = 19) completed two walking and cycling trials at self-selected speeds on a measured 1489-m course wearing two Garmin GPS units, worn in lanyard and Waistband placements. GPS estimates of travel distance were compared with actual distance, and test-retest reliability was examined. Data-cleaning protocols were developed to remove signal noise. Results are presented for both raw and cleaned data. Results: For both raw and cleaned data, no significant differences were observed between trials (trial 1 vs trial 2), unit placement (lanyard vs waistband), or AT mode (walk vs cycle) (P >= 0.05). Both lanyard and waistband units significantly overestimated distance traveled during walking trials (P <= 0.05), but not cycling trials (P >= 0.05). The relative technical error of measurement (TEM) of the raw data ranged from 3.74 to 15.51%, and average absolute errors ranged from 5.03 to 8.53% for all trials. A significant position by AT mode interaction was observed for clean data (P < 0.05). Relative TEM for the clean data ranged from 1.42 to 1.98%, and average absolute errors ranged from 0.32 to 1.97%. Intraclass correlations (ICC) were poor to fair for all trials using raw and cleaned data. Conclusion: Signal noise during unit initialization may adversely affect unit performance; however, application of data-cleaning procedures to remove data associated with signal noise improves unit ability to measure distance. Results suggest that the lanyard position is the optimal placement for units during data collection.
引用
收藏
页码:1851 / 1857
页数:7
相关论文
共 32 条
[21]   Proportion of trips made by walking:: Estimating a state-level baseline for Healthy People 2010 Objective 22-14 [J].
Rafferty, AP ;
McGee, HB ;
Petersmarck, KA ;
Miller, CE .
AMERICAN JOURNAL OF HEALTH PROMOTION, 2004, 18 (05) :387-391
[22]  
RORIGUEZ D, 2005, MED SCI SPORTS EXERC, V37, pS572
[23]   Could a satellite-based navigation system (GPS) be used to assess the physical activity of individuals on earth? [J].
Schutz, Y ;
Chambaz, A .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1997, 51 (05) :338-339
[24]   Assessment of speed of human locomotion using a differential satellite global positioning system [J].
Schutz, Y ;
Herren, R .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (03) :642-646
[25]   Measurement of the mechanical power of walking by satellite positioning system (GPS) [J].
Terrier, P ;
Ladetto, Q ;
Merminod, B ;
Schutz, Y .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (11) :1912-1918
[26]   How useful is satellite positioning system (GPS) to track gait parameters? A review [J].
Terrier P. ;
Schutz Y. .
Journal of NeuroEngineering and Rehabilitation, 2 (1)
[27]   Personal, family, social, and environmental correlates of active commuting to school [J].
Timperio, A ;
Ball, K ;
Salmon, J ;
Roberts, R ;
Giles-Corti, B ;
Simmons, D ;
Baur, LA ;
Crawford, D .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2006, 30 (01) :45-51
[28]   Correlates of recreational and transportation physical activity among adults in a New England community [J].
Troped, PJ ;
Saunders, RP ;
Pate, RR ;
Reininger, B ;
Addy, CL .
PREVENTIVE MEDICINE, 2003, 37 (04) :304-310
[29]  
Trost S G, 2001, Exerc Sport Sci Rev, V29, P32, DOI 10.1097/00003677-200101000-00007
[30]   Does reactivity exist in children when measuring activity levels with pedometers? [J].
Vincent, SD ;
Pangrazi, RP .
PEDIATRIC EXERCISE SCIENCE, 2002, 14 (01) :56-63