Particle swarm optimization for determining shortest distance to voltage collapse

被引:8
作者
Arya, L. D. [1 ]
Choube, S. C. [1 ]
Shrivastava, M. [2 ]
Kothari, D. P. [3 ]
机构
[1] SGSITS, Dept Elect Engn, Indore 452003, MP, India
[2] Govt Engn Coll Ujjain, Dept Elect Engn, Ujjain 456010, Madhya Pradesh, India
[3] Indian Inst Technol, Ctr Energy Studies, Delhi, India
关键词
voltage stability; CSNBP; particle swarm optimization; security;
D O I
10.1016/j.ijepes.2007.06.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an algorithm for computing shortest distance to voltage collapse or determination of CSNBP using PSO technique. A direction along CSNBP gives conservative results from voltage security view point. This information is useful to the operator to steer the system away from this point by taking corrective actions. The distance to a closest bifurcation is a minimum of the loadability given a slack bus or participation factors for increasing generation as the load increases. CSNBP determination has been formulated as an optimization problem to be used in PSO technique. PSO is a new evolutionary algorithm (EA) which is population based inspired by the social behavior of animals such as fish schooling and birds flocking. It can handle optimization problems with any complexity since mechanization is simple with few parameters to be tuned. The developed algorithm has been implemented on two standard test systems. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 25 条
[1]  
ABIDO MA, 2007, INT J ELECT POWER SY, V24, P563
[2]   THE CONTINUATION POWER FLOW - A TOOL FOR STEADY-STATE VOLTAGE STABILITY ANALYSIS [J].
AJJARAPU, V ;
CHRISTY, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :416-423
[3]   Corrective rescheduling for static voltage stability control [J].
Arya, LD ;
Sakravdia, DK ;
Kothari, DP .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (01) :3-12
[4]   CPFLOW - A PRACTICAL TOOL FOR TRACING POWER-SYSTEM STEADY-STATE STATIONARY BEHAVIOR DUE TO LOAD AND GENERATION VARIATIONS [J].
CHIANG, HD ;
FLUECK, AJ ;
SHAH, KS ;
BALU, N .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :623-630
[5]   A MORE EFFICIENT FORMULATION FOR COMPUTATION OF THE MAXIMUM LOADING POINTS IN ELECTRIC-POWER SYSTEMS [J].
CHIANG, HD ;
JEANJUMEAU, R .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :635-641
[6]   Voltage collapse risk assessment [J].
da Silva, AML ;
Coutinho, IP ;
de Souza, ACZ ;
Prada, RB ;
Rei, AM .
ELECTRIC POWER SYSTEMS RESEARCH, 2000, 54 (03) :221-227
[7]   COMPUTING AN OPTIMUM DIRECTION IN CONTROL SPACE TO AVOID SADDLE NODE BIFURCATION AND VOLTAGE COLLAPSE IN ELECTRIC-POWER SYSTEMS [J].
DOBSON, I ;
LU, LM .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1992, 37 (10) :1616-1620
[8]   NEW METHODS FOR COMPUTING A CLOSEST SADDLE NODE BIFURCATION AND WORST-CASE LOAD POWER MARGIN FOR VOLTAGE COLLAPSE [J].
DOBSON, I ;
LU, LM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (03) :905-913
[9]   Particle swarm optimization to solving the economic dispatch considering the generator constraints [J].
Gaing, ZL .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (03) :1187-1195
[10]   Direct calculation of reactive power limit points [J].
Hiskens, IA ;
Chakrabarti, BB .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1996, 18 (02) :121-129