Biomechanical analysis of an interference screw and a novel twist lock screw design for bone graft fixation

被引:4
作者
Asnis, S. [1 ,2 ]
Mullen, J. [1 ]
Asnis, P. D. [4 ]
Sgaglione, N. [1 ,2 ]
LaPorta, T. [1 ]
Grande, D. A. [1 ,2 ,3 ]
Chahine, N. O. [5 ]
机构
[1] Northwell Hlth, Dept Orthopaed Surg, LIJ Med Ctr, New Hyde Pk, NY USA
[2] Hofstra Northwell Sch Med, Dept Orthopaed Surg, Hempstead, NY USA
[3] Northwell Hlth, Feinstein Inst Med Res, Manhasset, NY USA
[4] Massachusetts Gen Hosp, Dept Orthopaed Surg, Div Sports Orthopaed Surg, Boston, MA 02114 USA
[5] Columbia Univ, Dept Orthoped Surg & Biomed Engn, New York, NY USA
关键词
Bone-tendon-bone fixation; Anterior cruciate ligament reconstruction; Screw fixation; Interference screw; Biomechanics; HOLDING POWER;
D O I
10.1016/j.clinbiomech.2017.10.007
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Malpositioning of an anterior cruciate ligament graft during reconstruction can occur during screw fixation. The purpose of this study is to compare the fixation biomechanics of a conventional interference screw with a novel Twist Lock Screw, a rectangular shaped locking screw that is designed to address limitations of graft positioning and tensioning. Methods: Synthetic bone (10, 15, 20 lb per cubic foot) were used simulating soft, moderate, and dense cancellous bone. Screw push-out and graft push-out tests were performed using conventional and twist lock screws. Maximum load and torque of insertion were measured. Findings: Max load measured in screw push out with twist lock screw was 64%, 60%, 57% of that measured with conventional screw in soft, moderate and dense material, respectively. Twist lock max load was 78% and 82% of that with conventional screw in soft and moderate densities. In the highest bone density, max loads were comparable in the two systems. Torque of insertion with twist lock was significantly lower than with conventional interference screw. Interpretation: Based on geometric consideration, the twist lock screw is expected to have 35% the holding power of a cylindrical screw. Yet, results indicate that holding power was greater than theoretical consideration, possibly due to lower friction and lower preloaded force. During graft push out in the densest material, comparable max loads were achieved with both systems, suggesting that fixation of higher density bone, which is observed in young athletes that require reconstruction, can be achieved with the twist lock screw.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 12 条
[1]
Cancellous bone screw thread design and holding power [J].
Asnis, SE ;
Ernberg, JJ ;
Bostrom, MPG ;
Wright, TM ;
Harrington, RM ;
Tencer, A ;
Peterson, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) :462-469
[2]
Asnis SE., 1997, ADV PODIATRIC MED SU, V3, P57
[3]
Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[4]
Collinge CA, 2000, CLIN ORTHOP RELAT R, P277
[5]
A Comparison of the Results of Anterior Cruciate Ligament Reconstruction Using Bioabsorbable Versus Metal Interference Screws A Meta-Analysis [J].
Emond, Christopher E. ;
Woelber, Erik B. ;
Kurd, Shanu K. ;
Ciccotti, Michael G. ;
Cohen, Steven B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (06) :572-580
[6]
The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro [J].
Halewood, Camilla ;
Hirschmann, Michael T. ;
Newman, Simon ;
Hleihil, Jaffar ;
Chaimski, Gershon ;
Amis, Andrew A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (04) :559-567
[7]
KLEEMAN BC, 1992, CLIN ORTHOP RELAT R, P260
[8]
KORANYI E, 1970, CLIN ORTHOP RELAT R, P283
[9]
The Effect of Interference Screw Diameter on Fixation of Soft-Tissue Grafts in Anterior Cruciate Ligament Reconstruction [J].
Micucci, Chad J. ;
Frank, Darren A. ;
Kompel, John ;
Muffly, Matthew ;
DeMeo, Patrick J. ;
Altman, Gregory T. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (08) :1105-1110
[10]
Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: Are all screws created equal? [J].
Ramaswamy, Rajesh ;
Evans, Samuel ;
Kosashvili, Yona .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02) :179-183