Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: Are all screws created equal?

被引:79
作者
Ramaswamy, Rajesh [3 ]
Evans, Samuel [2 ]
Kosashvili, Yona [1 ]
机构
[1] Univ Toronto, Mt Sinai Hosp, Dept Orthoped, Toronto, ON M5S 1A1, Canada
[2] Cardiff Univ, Dept Engn, Cardiff, S Glam, Wales
[3] Univ Toronto, Sunnybrook Med Hlth Sci Ctr, Toronto, ON M5S 1A1, Canada
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2010年 / 41卷 / 02期
关键词
Osteoporosis; Scaphoid fractures; Variable pitch screw; Holding strength; COMPRESSION FORCES; FIXATION;
D O I
10.1016/j.injury.2009.08.015
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Introduction: Biomechanical properties of four different commercially available small fragment cannulated screws (Twin fix (Stryker, Freiburg, Germany), Herbert, (Zimmer, Warsaw, USA), Omnitech (Unimedical, Torino, Italy), Barouk (Depuy, Warsaw, USA)), with variable pitch, used for fracture fixation were compared. Materials and methods: Polyurethane foam blocks of three different densities with mechanical properties similar to osteoporotic, osteopenic and normal bones were used to conduct the tests. Each screw was tested for pushout and pullout holding power after a primary insertion and for pullout after a repeated insertion into the respective foam blocks. Results: The mean pullout and pushout strengths of all screws correlated to the foam density, and were significantly (p < 0.001 and <0.001, respectively) better in foam with higher density. The mean pullout strength of each screw was consistently lower after reinsertion into the osteoporotic, osteopenic and normal bone densities by 4-30%, when compared to the index insertion (Fig. 4b). Yet, this difference was not found to be statistically significant (p = 0.23). The Barouk screw performed significantly (p < 0.0001) better than the other screws in all three different densities of foam for both for pushout and pullout after index insertion as well as for pullout tests after reinsertion, Conclusion: The holding power of screws is directly correlated to bone density, thread design and number of threads engaging the bone. Reinsertion through the same hole could reduce the ultimate pullout strength. The surgeon should consider the advantages and disadvantages of each implant, depending on the clinical situation and choose accordingly. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 183
页数:5
相关论文
共 19 条
[1]
Compression forces generated by Mini bone screws - a comparative study done on bone model [J].
Adla, DN ;
Kitsis, C ;
Miles, AW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01) :65-70
[2]
[Anonymous], 2002, F183901 ASTM
[3]
Cancellous bone screw thread design and holding power [J].
Asnis, SE ;
Ernberg, JJ ;
Bostrom, MPG ;
Wright, TM ;
Harrington, RM ;
Tencer, A ;
Peterson, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) :462-469
[4]
Barouk L S, 2000, Foot Ankle Clin, V5, P525
[5]
Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[6]
COLLINGE CA, 2000, CLIN ORTHOP RELAT R, V373, P277
[7]
Cook Stephen D, 2004, Spine J, V4, P402, DOI 10.1016/j.spinee.2003.11.010
[8]
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[9]
Clinical and radiological outcome of cast immobilisation versus surgical treatment of acute scaphoid fractures at a mean follow-up of 93 months [J].
Dias, J. J. ;
Dhukaram, V. ;
Abhinav, A. ;
Bhowal, B. ;
Wildin, C. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07) :899-905
[10]
Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model [J].
Hausmann, J. T. ;
Mayr, W. ;
Unger, E. ;
Benesch, T. ;
Vecsei, V. ;
Gaebler, C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07) :763-768