Comprehensive biocompatibility testing of a new PMMA-HA bone cement versus conventional PMMA cement in vitro

被引:52
作者
Jäger, M
Wilke, A
机构
[1] Univ Dusseldorf, Sch Med, Dept Orthopaed, D-40225 Dusseldorf, Germany
[2] Univ Marburg, Sch Med, Dept Orthopaed, Klinikum Lahnberge, D-35043 Marburg, Germany
关键词
bone cement; bone marrow cell culture; biocompatibility; hydroxyapatite;
D O I
10.1163/156856203322553491
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For more than 50 years PMMA bone cements have been used in orthopaedic surgery. In this study attempts were made to show whether cultured human bone marrow cells (HBMC) show an osteogenetic response resulting in new bone formation, production of extracellular matrix (ECM) and cell differentiation when they were cultured onto polymerized polymethyl methacryl ate (PMMA)hydroxyapatite (HA), conventional PMMA bone cement being taken as reference. Biocompatibility parameters were collagen-I and -III synthesis, the detection of the osteoblast markers alkaline phosphatase (ALP) and osteocalcin, the number of adherent cells and the cytodifferentiation of immunocompetent cells. Cement surface structure, HA stability in culture medium and chemical element analysis of specimens were considered. Fresh marrow cells were obtained from the human femora during hip replacement. Incubation time was up to ten weeks. We used atomic forced microscopy (AFM) and scanning electron microscopy (SEM) for cement specimen analysis. Fluorescent activated cell sorter (FACS), immunohistochemical staining, SEM and light microscopy (LM) served us to judge the cellular morphology. Products of the extracellular matrix were analyzed by protein dot blot analysis, SEM energy dispersive X-ray analysis (SEM-EDX) and Ca2+/PO43- detection. HA particles increased the osteogenetic potential of PMMA bone cement regarding the cellular production of collagen, alkaline phosphatase (AP), the number of osteoblasts and the cellular differentiation pattern in vitro. Both tested cements showed good biocompatibility in a human long-term bone marrow cell-culture system.
引用
收藏
页码:1283 / 1298
页数:16
相关论文
共 39 条
[31]   LACK OF IMMUNE-RESPONSE TO METHYL-METHACRYLATE IN LYMPHOCYTE-CULTURES [J].
SANTAVIRTA, S ;
KONTTINEN, YT ;
BERGROTH, V ;
GRONBLAD, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (01) :29-32
[32]   Evaluation of bioresorbable polymers of lactic acid in a culture of human bone marrow cells [J].
Stemberg, F ;
Wilke, A .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2001, 12 (02) :171-184
[33]  
Wight Thomas N., 1992, Current Opinion in Cell Biology, V4, P793, DOI 10.1016/0955-0674(92)90102-I
[34]  
Wilke A, 1998, J BIOMED MATER RES, V40, P301, DOI 10.1002/(SICI)1097-4636(199805)40:2<301::AID-JBM15>3.0.CO
[35]  
2-O
[36]  
WILKE A, 2002, EUR J TRAUMA, V5, P279
[37]   REACTIONS OF ARTICULAR CAPSULE TO WEAR PRODUCTS OF ARTIFICIAL JOINT PROSTHESES [J].
WILLERT, HG ;
SEMLITSCH, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (02) :157-164
[38]  
Zreiqat H, 1999, J BIOMED MATER RES, V44, P389, DOI 10.1002/(SICI)1097-4636(19990315)44:4<389::AID-JBM4>3.0.CO
[39]  
2-O