The effects of atrial electrical remodeling on atrial defibrillation thresholds

被引:8
作者
Everett, TH [1 ]
Li, H [1 ]
Mangrum, JM [1 ]
Mastrangelo, C [1 ]
Haines, DE [1 ]
机构
[1] Univ Virginia, Hlth Sci Ctr, Div Cardiovasc, Dept Internal Med, Charlottesville, VA 22908 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 08期
关键词
atrial fibrillation; electrical remodeling; defibrillation; atrial implantable defibrillator; pacing;
D O I
10.1046/j.1460-9592.2001.01208.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Electrical remodeling of atrial fibrillation may account for the increase in atrial defibrillation thresholds over time. The aim of this study was to examine the time course of electrical remodeling and the benefit of early defibrillation on the defibrillation threshold, Twenty-six mongrel dogs weighing 27.6 +/-3.3 kg were induced into AF by repeated high output burst atrial pacing. Eight dogs were paced for multiple time periods of 5, 20, 40, and 60 minutes. Five dogs each had burst pacing for 4 hours and 8 hours, and eight dogs were paced at a high rate (640 beats/min) for 48 hours. Biphasic atrial defibrillation shocks with a pulse width of 3/3 ms synchronized to the left apical electrogram were delivered to coil electrode catheters positioned in the lateral left and right atria. Defibrillation voltage was increased from 50 V in 20- to 30-V steps until defibrillation was successful. As the pacing period increased, a decrease in atrial fibrillation cycle lengths and atrial effective refractory period was not observed before 8 hours. Similarly, the defibrillation threshold did not change significantly until the 8-hour pacing period was reached. The defibrillation thresholds were 69 +/- 28 Vfor 5 minutes, 64 +/- 20 Vfor 20 minutes, 99 +/- 85 Vfor 40 minutes, 78 +/- 51 Vfor 60 minutes, 78 +/- 38 Vfor 4 hours, 124 +/- 33 Vfor 8 hours, and 133 +/- 32 Vfor 48 hours (mean SD) (P < 0.05). Atrial electrical remodeling in a rapid atrial pacing canine model is not observed until after 4 hours of burst atrail pacing. The atrial defibrillation threshold increases with increasing duration of burst atrial pacing, and follows a similar time course to other parameters of electrical remodeling.
引用
收藏
页码:1208 / 1215
页数:8
相关论文
共 37 条
[1]
Allesie MA, 1990, CARDIAC ELECTROPHYSI, P548
[2]
Electrophysiologic mechanisms of perpetuation of atrial fibrillation [J].
Allessie, MA ;
Konings, K ;
Kirchhof, CJHJ ;
Wijffels, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (03) :A10-A23
[3]
Brachmann J, 1998, J CARDIOVASC ELECTR, V9, pS35
[4]
Capture window in human atrial fibrillation: Evidence of an excitable gap [J].
Capucci, A ;
Ravelli, F ;
Nollo, G ;
Montenero, AS ;
Biffi, M ;
Villani, GQ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (03) :319-327
[5]
Carlson Mark D., 1996, Cardiology Clinics, V14, P607
[6]
Internal cardioversion of atrial fibrillation - Marked reduction in defibrillation threshold with dual current pathways [J].
Cooper, RAS ;
Smith, WM ;
Ideker, RE .
CIRCULATION, 1997, 96 (08) :2693-2700
[7]
INTERNAL CARDIOVERSION OF ATRIAL-FIBRILLATION IN SHEEP [J].
COOPER, RAS ;
ALFERNESS, CA ;
SMITH, WM ;
IDEKER, RE .
CIRCULATION, 1993, 87 (05) :1673-1686
[8]
Effect of atrial fibrillation on atrial refractoriness in humans [J].
Daoud, EG ;
Begun, F ;
Goyal, R ;
Harvey, M ;
Man, KC ;
Strickberger, SA ;
Morady, F .
CIRCULATION, 1996, 94 (07) :1600-1606
[9]
Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs - Electrophysiological remodeling [J].
Elvan, A ;
Wylie, K ;
Zipes, DP .
CIRCULATION, 1996, 94 (11) :2953-2960
[10]
Importance of refractoriness heterogeneity in the enhanced vulnerability to atrial fibrillation induction caused by tachycardia-induced atrial electrical remodeling [J].
Fareh, S ;
Villemaire, C ;
Nattel, S .
CIRCULATION, 1998, 98 (20) :2202-2209