Four-channel optically pumped atomic magnetometer for magnetoencephalography

被引:129
作者
Colombo, Anthony P. [1 ]
Carter, Tony R. [1 ]
Borna, Amir [1 ]
Jau, Yuan-Yu [1 ]
Johnson, Cort N. [1 ,2 ]
Dagel, Amber L. [1 ]
Schwindt, Peter D. D. [1 ]
机构
[1] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[2] Charles Stark Draper Lab, 555 Technol Sq, Cambridge, MA 02139 USA
来源
OPTICS EXPRESS | 2016年 / 24卷 / 14期
基金
美国国家卫生研究院;
关键词
FETAL MAGNETOCARDIOGRAPHY; ARRAY; FIELDS;
D O I
10.1364/OE.24.015403
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz(1/2), and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. This module will serve as a building block of an array for magnetic source localization. (C) 2016 Optical Society of America
引用
收藏
页码:15403 / 15416
页数:14
相关论文
共 42 条
[1]   Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers [J].
Alem, Orang ;
Sander, Tilmann H. ;
Mhaskar, Rahul ;
LeBlanc, John ;
Eswaran, Hari ;
Steinhoff, Uwe ;
Okada, Yoshio ;
Kitching, John ;
Trahms, Lutz ;
Knappe, Svenja .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12) :4797-4811
[2]   Magnetoencephalography of Epilepsy with a Microfabricated Atomic Magnetrode [J].
Alem, Orang ;
Benison, Alex M. ;
Barth, Daniel S. ;
Kitching, John ;
Knappe, Svenja .
JOURNAL OF NEUROSCIENCE, 2014, 34 (43) :14324-14327
[3]   High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation [J].
Allred, JC ;
Lyman, RN ;
Kornack, TW ;
Romalis, MV .
PHYSICAL REVIEW LETTERS, 2002, 89 (13) :130801-130801
[4]   Theory of spin-exchange optical pumping of 3He and 129Xe [J].
Appelt, S ;
Baranga, AB ;
Erickson, CJ ;
Romalis, MV ;
Young, AR ;
Happer, W .
PHYSICAL REVIEW A, 1998, 58 (02) :1412-1439
[5]   Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment [J].
Belfi, J. ;
Bevilacqua, G. ;
Biancalana, V. ;
Cartaleva, S. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2007, 24 (09) :2357-2362
[6]   Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor [J].
Bison, G ;
Wynands, R ;
Weis, A .
OPTICS EXPRESS, 2003, 11 (08) :904-909
[7]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[8]   A room temperature 19-channel magnetic field mapping device for cardiac signals [J].
Bison, G. ;
Castagna, N. ;
Hofer, A. ;
Knowles, P. ;
Schenker, J. -L. ;
Kasprzak, M. ;
Saudan, H. ;
Weis, A. .
APPLIED PHYSICS LETTERS, 2009, 95 (17)
[9]   Skew light propagation in optically thick optical pumping cells [J].
Chann, B ;
Babcock, E ;
Anderson, LW ;
Walker, TG .
PHYSICAL REVIEW A, 2002, 66 (03) :3
[10]   EXPERIMENTAL STUDY OF ZEEMAN LIGHT SHIFTS IN WEAK MAGNETIC-FIELDS [J].
COHENTANNOUDJI, C ;
DUPONTRO.J .
PHYSICAL REVIEW A-GENERAL PHYSICS, 1972, 5 (02) :968-+