Measurement of the Casimir force between dissimilar metals -: art. no. 050402

被引:273
作者
Decca, RS [1 ]
López, D
Fischbach, E
Krause, DE
机构
[1] Indiana Univ Purdue Univ, Dept Phys, Indianapolis, IN 46202 USA
[2] Bell Labs, Lucent Technol, Murray Hill, NJ 07974 USA
[3] Purdue Univ, Dept Phys, W Lafayette, IN 47907 USA
[4] Wabash Coll, Dept Phys, Crawfordsville, IN 47933 USA
关键词
D O I
10.1103/PhysRevLett.91.050402
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The first precise measurement of the Casimir force between dissimilar metals is reported. The attractive force, between a Cu layer evaporated on a microelectromechanical torsional oscillator and an Au layer deposited on an Al2O3 sphere, was measured dynamically with a noise level of 6 fN/rootHz. Measurements were performed for separations in the 0.2-2 mum range. The results agree to better than 1% in the 0.2-0.5 mum range with a theoretical model that takes into account the finite conductivity and roughness of the two metals. The observed discrepancies, which are much larger than the experimental precision, can be attributed to a lack of a complete characterization of the optical properties of the specific samples used in the experiment.
引用
收藏
页数:4
相关论文
共 36 条
[21]   Casimir and van der Waals forces between two plates or a sphere (lens) above a plate made of real metals [J].
Klimchitskaya, GL ;
Mohideen, U ;
Mostepanenko, VM .
PHYSICAL REVIEW A, 2000, 61 (06) :12
[22]   Complete roughness and conductivity corrections for Casimir force measurement [J].
Klimchitskaya, GL ;
Roy, A ;
Mohideen, U ;
Mostepanenko, VM .
PHYSICAL REVIEW A, 1999, 60 (05) :3487-3495
[23]   Capacitive sensor for micropositioning in two dimensions [J].
Kolb, PW ;
Decca, RS ;
Drew, HD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01) :310-312
[24]   Isotopic dependence of the Casimir force [J].
Krause, DE ;
Fischbach, E .
PHYSICAL REVIEW LETTERS, 2002, 89 (19)
[25]  
KRAUSE DE, 2001, GYROS CLOOCKS INTERF
[26]  
KRAUSE DE, 2002, 9 M GROSSM M
[27]   Casimir force between metallic mirrors [J].
Lambrecht, A ;
Reynaud, S .
EUROPEAN PHYSICAL JOURNAL D, 2000, 8 (03) :309-318
[28]   Calculation of the Casimir force between imperfectly conducting plates [J].
Lamoreaux, SK .
PHYSICAL REVIEW A, 1999, 59 (05) :R3149-R3153
[29]   Demonstration of the casimir force in the 0.6 to 6 mu m range [J].
Lamoreaux, SK .
PHYSICAL REVIEW LETTERS, 1997, 78 (01) :5-8
[30]  
LIFSHITZ EM, 1956, SOV PHYS JETP-USSR, V2, P73