In vivo monitoring of the thiols in rat striatum by liquid chromatography with amperometric detection at a functionalized multi-wall carbon nanotubes modified electrode

被引:23
作者
Cao, XN
Lin, L
Xian, YZ
Zhang, W
Xie, YF
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] Wenzhou Med Coll, Dept Chem, Zhejiang 325027, Peoples R China
关键词
functionlized multi-wall carbon nanotubes; chemically modified electrode; HPLC-ECD; thiols; microdialysis; rat striatum;
D O I
10.1002/elan.200390111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chemically modified electrode (CME) was fabricated, which was based on the immobilization of multi-wall carbon nanotubes fuctionalized with carboxylic group (MWNT-COOH). The results indicated that the CME exhibited efficiently electrocatalytic oxidation for L-cysteine and glutathione with relatively high sensitivity, stability and long-life. Coupled with HPLC, the MWNT-COOH CME was utilized for amperometric detection of the thiols. The peak currents of L-cysteine and glutathione were linear to their concentrations ranging from 3.0x10(-7) to 1.0x10(-3) mol/L with the calculated detection limit (S/N=3) of 1.2x10(-7), 2.2x10(-7) mol/L, respectively. The method had been successfully applied to assess the contents of L-cysteine and glutathione in rat striatal microdialysates.
引用
收藏
页码:892 / 897
页数:6
相关论文
共 33 条
[21]   Atomic structure and electronic properties of single-walled carbon nanotubes [J].
Odom, TW ;
Huang, JL ;
Kim, P ;
Lieber, CM .
NATURE, 1998, 391 (6662) :62-64
[22]  
OLENEY JW, 1990, SCIENCE, V248, P596
[23]  
Orlowski M, 1976, Int Rev Neurobiol, V19, P75, DOI 10.1016/S0074-7742(08)60702-3
[24]   SELECTIVE DETECTION OF FREE THIOLS BY CAPILLARY ELECTROPHORESIS ELECTROCHEMISTRY USING A GOLD MERCURY AMALGAM MICROELECTRODE [J].
OSHEA, TJ ;
LUNTE, SM .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :247-250
[25]   CHEMICALLY-MODIFIED MICROELECTRODES FOR CAPILLARY ELECTROPHORESIS ELECTROCHEMISTRY [J].
OSHEA, TJ ;
LUNTE, SM .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :307-311
[26]   MERCURY-BASED ELECTROCHEMICAL DETECTOR FOR LIQUID-CHROMATOGRAPHY FOR DETECTION OF GLUTATHIONE AND OTHER SULFUR-CONTAINING-COMPOUNDS [J].
RABENSTEIN, DL ;
SAETRE, R .
ANALYTICAL CHEMISTRY, 1977, 49 (07) :1036-1039
[27]   UNRAVELING NANOTUBES - FIELD-EMISSION FROM AN ATOMIC WIRE [J].
RINZLER, AG ;
HAFNER, JH ;
NIKOLAEV, P ;
LOU, L ;
KIM, SG ;
TOMANEK, D ;
NORDLANDER, P ;
COLBERT, DT ;
SMALLEY, RE .
SCIENCE, 1995, 269 (5230) :1550-1553
[28]   ELECTRONIC-STRUCTURE OF CHIRAL GRAPHENE TUBULES [J].
SAITO, R ;
FUJITA, M ;
DRESSELHAUS, G ;
DRESSELHAUS, MS .
APPLIED PHYSICS LETTERS, 1992, 60 (18) :2204-2206
[29]   BRAIN ISCHEMIA MARKEDLY ELEVATES LEVELS OF THE NEUROTOXIC AMINO-ACID, CYSTEINE [J].
SLIVKA, A ;
COHEN, G .
BRAIN RESEARCH, 1993, 608 (01) :33-37
[30]   Determination of thiols following their separation by CZE with amperometric detection at a carbon electrode [J].
Wang, A ;
Zhang, L ;
Zhang, S ;
Fang, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) :429-436