Simultaneous analysis of several antiretroviral nucleosides in rat-plasma by high-performance liquid chromatography with UV using acetic acid/hydroxylamine buffer - Test of this new volatile medium-pH for HPLC-ESI-MS/MS

被引:53
作者
Bezy, V
Morin, P [1 ]
Couerbe, P
Leleu, G
Agrofoglio, L
机构
[1] Univ Orleans, Inst Chim Organ & Analyt, CNRS, UMR 6005, F-45067 Orleans, France
[2] Bristol Myers Squibb Co, F-44600 St Nazaire, France
[3] Bristol Myers Squibb Co, Antiefect Immunol Dept, F-92500 Rueil Malmaison, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 821卷 / 02期
关键词
HPLC; hydroxylamine acetate buffer; nucleoside; antiretroviral; HIV plasma; mass spectrometry;
D O I
10.1016/j.jchromb.2005.04.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Zalcitabine (ddC), lamivudine (3TC), didanosine (ddI), stavudine (d4T), carbovir (CBV), zidovudine (AZT), tenofovir (PMPA) and its administrated form (tenofovir diisoproxyl fumarate, TDF), are nucleosides currently approved in HIV therapy. To facilitate pharmacokinetics studies, a specific reversed-phase high-performance liquid chromatography (HPLC) method was developed for their analysis in rat plasma. The method involved a quantitative recovery of these drugs from rat plasma by solid-phase extraction on Oasis((R)) HLB Waters cartridges followed by optimised HPLC separation on an Atlantis (TM) dC(18) column with acetic acid-hydroxylamine buffer (ionic strength 5 mM, pH 7)-acetonitrile elution gradient. Quantitation was performed by HPLC/UV at 260 nm. Linear calibration curves were obtained within a 30-10,000 ng/mL plasma concentration range. Correlation coefficients (12) greater than 0.992 were obtained by least-squares regression and limits of quantification were in 30-90 ng/mL concentration range. Quantitative parameters (accuracy, intra-day repeatability and inter-day reproducibility) yielded satisfactory results. Finally, a new buffer, obtained with acetic acid and hydroxylamine, has been tested in HPLC/ESI-MS/MS and appears to be an efficient volatile buffer in the medium 5-7 pH range. Indeed, at pH 7 and low ionic strength (5 mM), its buffer capacity is one hundred times higher to that obtained for the usual acetic acid/ammonia buffer. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 143
页数:12
相关论文
共 17 条
[1]  
Agrofoglio L, 1998, ACYCLIC CARBOCYCLIC
[2]   Determination of twelve antiretroviral agents in human plasma sample using reversed-phase high-performance liquid chromatography [J].
Aymard, G ;
Legrand, M ;
Trichereau, N ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 744 (02) :227-240
[3]   Pharmacokinetics and potential interactions amongst antiretroviral agents used to treat patients with HIV infection [J].
Barry, M ;
Mulcahy, F ;
Merry, C ;
Gibbons, S ;
Back, D .
CLINICAL PHARMACOKINETICS, 1999, 36 (04) :289-304
[4]   Concentration-controlled zidovudine therapy [J].
Fletcher, CV ;
Acosta, EP ;
Henry, K ;
Page, LM ;
Gross, CR ;
Kawle, SP ;
Remmel, RP ;
Erice, A ;
Balfour, HH .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1998, 64 (03) :331-338
[5]   PHOSPHORYLATION OF 3'-AZIDO-3'-DEOXYTHYMIDINE AND SELECTIVE INTERACTION OF THE 5'-TRIPHOSPHATE WITH HUMAN-IMMUNODEFICIENCY-VIRUS REVERSE-TRANSCRIPTASE [J].
FURMAN, PA ;
FYFE, JA ;
STCLAIR, MH ;
WEINHOLD, K ;
RIDEOUT, JL ;
FREEMAN, GA ;
LEHRMAN, SN ;
BOLOGNESI, DP ;
BRODER, S ;
MITSUYA, H ;
BARRY, DW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (21) :8333-8337
[6]  
HENION MC, 1981, J CHROMATOGR, V210, P211
[7]   Simultaneous determination of zidovudine and lamivudine in human serum using HPLC with tandem mass spectrometry [J].
Kenney, KB ;
Wring, SA ;
Carr, RM ;
Wells, GN ;
Dunn, JA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (06) :967-983
[8]   QUANTITATION OF DIDANOSINE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KNUPP, CA ;
STANCATO, FA ;
PAPP, EA ;
BARBHAIYA, RH .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 533 :282-290
[9]   Simultaneous determination of lamivudine and zidovudine concentrations in human seminal plasma using high-performance liquid chromatography and tandem mass spectrometry [J].
Pereira, AS ;
Kenney, KB ;
Cohen, MS ;
Hall, JE ;
Eron, JJ ;
Tidwell, RR ;
Dunn, JA .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (01) :173-183
[10]   Simultaneous determination of six HIV nucleoside analogue reverse transcriptase inhibitors and nevirapine by liquid chromatography with ultraviolet absorbance detection [J].
Rezk, NL ;
Tidwell, RR ;
Kashuba, ADM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2) :137-147