Geometry of thoracolumbar vertebral endplates of the human spine

被引:19
作者
Chen, Hong [1 ]
Jiang, Dianming [1 ]
Ou, Yunsheng [1 ]
Zhong, Jian [1 ]
Lv, Fajin [2 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 1, Dept Orthoped, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, Chongqing 400016, Peoples R China
关键词
Geometry; Thoracolumbar spine; Vertebral endplate; Vertebral body replacement; HUMAN LUMBAR VERTEBRAE; TITANIUM MESH CAGES; BODY REPLACEMENT; BIOMECHANICS; STRENGTH; MORPHOLOGY; BONE;
D O I
10.1007/s00586-011-1787-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Novel and better vertebral body replacement constructs are always desired by surgeons. Endplate geometry is crucial for the design of those implants, but current literature on that topic is very scarce. The authors present a morphometric study of thoracolumbar vertebral endplates, the goal of which was to analyze the geometry of endplates from T10 inferior to L3 superior by employing data from CT scans, as well as to verify the reliability of data derived from the CT measurement. Reformatted CT scans of 83 individuals were analyzed and sagittal concave angle, location of concave region, sagittal diameter of endplate, coronal concave angle, as well as transverse diameter of endplate were measured in midsagittal plane and specified coronal plane. The data of CT and cadaveric measurements of ten cadaveric specimens were also compared. Age and gender did not influence sagittal concave angle, location of concave region, and coronal concave angle significantly (P > 0.05). No significant difference has been revealed among each endplate for sagittal concave angle (range 162.5A degrees-163.9A degrees) and location of concave region (range 42.5-44.2%), either. Ranging between 170.9A degrees and 175.7A degrees, coronal concave angle was constantly larger in superior endplate than in inferior one. The sagittal and transverse endplate diameters of females were significantly smaller than those of males (P < 0.05), being about 88% of the latter one. The mean difference between CT and cadaveric measurements was small (Cronbach alpha > 0.8). Those morphologic parameters, especially the concavity of endplates, should be taken into consideration when designing novel vertebral body replacement constructs. CT measurement data could be used to calculate most suitable geometric parameters of those implants.
引用
收藏
页码:1814 / 1820
页数:7
相关论文
共 21 条
[1]
A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[2]
Cronbach's alpha [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1997, 314 (7080) :572-572
[3]
In vitro biomechanics of an expandable vertebral body replacement with self-adjusting end plates [J].
Buttermann, Glenn R. ;
Freeman, Andrew L. ;
Beaubien, Brian P. .
SPINE JOURNAL, 2010, 10 (11) :1024-1031
[4]
Interbody device endplate engagement effects on motion segment biomechanics [J].
Buttermann, Glenn R. ;
Beaubien, Brian P. ;
Freeman, Andrew L. ;
Stoll, James E. ;
Chappuis, James L. .
SPINE JOURNAL, 2009, 9 (07) :564-573
[5]
Treatment of tuberculous spondylitis with anterior stabilization and titanium cage [J].
Christodoulou, Anastasios G. ;
Givissis, Panagiotis ;
Karataglis, Dimitrios ;
Symeonidis, Panagiotis D. ;
Pournaras, John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) :60-65
[6]
Edwards WT, 2001, SPINE, V26, P218
[7]
Biomechanics of the aging spine [J].
Ferguson, SJ ;
Steffen, T .
EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) :S97-S103
[8]
A STUDY OF VERTEBRA AND DISK GEOMETRIC RELATIONS OF THE HUMAN CERVICAL AND LUMBAR SPINE [J].
GILAD, I ;
NISSAN, M .
SPINE, 1986, 11 (02) :154-157
[9]
Titanium mesh cages (TMC) in spine surgery [J].
Grob, D ;
Daehn, S ;
Mannion, AF .
EUROPEAN SPINE JOURNAL, 2005, 14 (03) :211-221
[10]
Morphology of the lumbar vertebral endplates [J].
Hall, LT ;
Esses, SI ;
Noble, PC ;
Kamaric, E .
SPINE, 1998, 23 (14) :1517-1522