High-resolution biosensor spectral peak shift estimation

被引:14
作者
Karl, WC [1 ]
Pien, HH
机构
[1] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[3] SRU Biosyst, Woburn, MA 01801 USA
关键词
Cramer-Rao bounds; high resolution; maximum likelihood; optical resonant biosensor; spectral peak shift estimation;
D O I
10.1109/TSP.2005.859215
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a maximum likelihood (NIL) approach to high-resolution estimation of the shifts of a spectral signal. This spectral signal arises in application of optically based resonant biosensors, where high resolution in the estimation of signal shift is synonymous with high sensitivity to biological interactions. For the particular sensor of interest, the underlying signal is nonuniformly sampled and exhibits Poisson amplitude statistics. Shift estimation accuracies orders of magnitude finer than the sample spacing are sought. The new NIL-based formulation leads to a solution approach different from typical resonance shift E estimation methods based on polynomial fitting and peak (or null) estimation and tracking.
引用
收藏
页码:4631 / 4639
页数:9
相关论文
共 28 条
[11]   PRINCIPLES OF BIOSENSING WITH AN EXTENDED COUPLING MATRIX AND SURFACE-PLASMON RESONANCE [J].
LIEDBERG, B ;
LUNDSTROM, I ;
STENBERG, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :63-72
[12]   SURFACE-PLASMON RESONANCE FOR GAS-DETECTION AND BIOSENSING [J].
LIEDBERG, B ;
NYLANDER, C ;
LUNDSTROM, I .
SENSORS AND ACTUATORS, 1983, 4 (02) :299-304
[13]   A label-free optical technique for detecting small molecule interactions [J].
Lin, B ;
Qiu, J ;
Gerstenmeier, J ;
Li, P ;
Pien, HM ;
Pepper, J ;
Cunningham, B .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :827-834
[14]   Experimental and computational approaches to estimate solubility and permeability in drug discovery and development settings (Reprinted from Advanced Drug Delivery Reviews, vol 23, pg 3-25, 1997) [J].
Lipinski, CA ;
Lombardo, F ;
Dominy, BW ;
Feeney, PJ .
ADVANCED DRUG DELIVERY REVIEWS, 2001, 46 (1-3) :3-26
[15]  
MA W, 1996, IEEE T SIGNAL PROCES, V44, P2669
[16]   A LEAST-SQUARES ALGORITHM FOR MULTIPATH TIME-DELAY ESTIMATION [J].
MANICKAM, TG ;
VACCARO, RJ ;
TUFTS, DW .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1994, 42 (11) :3229-3233
[17]  
Rao C.R., 1999, LINEAR MODELS LEAST
[18]   High-resolution and high-throughput protocols for measuring drug/human serum albumin interactions using BIACORE [J].
Rich, RL ;
Day, YSN ;
Morton, TA ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2001, 296 (02) :197-207
[19]  
SJOLANDER S, 1991, ANAL CHEM, V63, P2338
[20]   A fast direct fourier-based algorithm for subpixel registration of images [J].
Stone, HS ;
Orchard, MT ;
Chang, EC ;
Martucci, SA .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2001, 39 (10) :2235-2243