Biosensors based on electropolymerized films: new trends

被引:215
作者
Cosnier, S [1 ]
机构
[1] Univ Grenoble 1, CNRS, Inst Chim Mol Grenoble, UMR 5630,Lab Electrochim Organ & Photochim Redox, F-38041 Grenoble 9, France
关键词
biosensors; biochips; polypyrrole; electropolymerized films; enzyme electrode; protein immobilization;
D O I
10.1007/s00216-003-2131-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electropolymerized films have received considerable attention in the development of biosensors and biochips, and are advancing rapidly. This paper reviews recent advances and scientific progress in electrochemical immobilization procedures for biological macromolecules on electrodes via electrogenerated polymer films. Biomolecule immobilization is classified as covalent linkage, attachment by affinity interactions, and physical entrapment. The last approach entails the use of conducting and non-conducting films, composite polymer films, and templates for the electropolymerization process. Some advances in the electrochemical transduction of biological events (enzymatic reaction, immunoreaction, or oligonucleotide hybridization) involving the redox properties or the conductivity of electropolymerized films are also presented.
引用
收藏
页码:507 / 520
页数:14
相关论文
共 148 条
  • [81] Electropolymerisable pyrrole-oligonucleotide: synthesis and analysis of ODN hybridisation by fluorescence and QCM
    Lassalle, N
    Roget, A
    Livache, T
    Mailley, P
    Vieil, E
    [J]. TALANTA, 2001, 55 (05) : 993 - 1004
  • [82] Direct DNA hybridization detection based on the oligonucleotide-functionalized conductive polymer
    Lee, TY
    Shim, YB
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5629 - 5632
  • [83] Leipert D, 1998, ANGEW CHEM INT EDIT, V37, P2338
  • [84] PREPARATION OF A DNA MATRIX VIA AN ELECTROCHEMICALLY DIRECTED COPOLYMERIZATION OF PYRROLE AND OLIGONUCLEOTIDES BEARING A PYRROLE GROUP
    LIVACHE, T
    ROGET, A
    DEJEAN, E
    BARTHET, C
    BIDAN, G
    TEOULE, R
    [J]. NUCLEIC ACIDS RESEARCH, 1994, 22 (15) : 2915 - 2921
  • [85] A three-enzyme microelectrode sensor for detecting purine release from central nervous system
    Llaudet, E
    Botting, NP
    Crayston, JA
    Dale, N
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) : 43 - 52
  • [86] Amperometric hydrogen peroxide sensor electrodes coated with electropolymerized tyrosine derivative and phenolic films
    Long, DD
    Marx, KA
    Zhou, T
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2): : 107 - 113
  • [87] CHARACTERIZATION OF GLUCOSE OXIDASE-MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES IN-VITRO AND IN-VIVO - HOMOGENEOUS INTERFERENCE BY ASCORBIC-ACID IN HYDROGEN-PEROXIDE DETECTION
    LOWRY, JP
    MCATEER, K
    ELATRASH, SS
    DUFF, A
    ONEILL, RD
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (10) : 1754 - 1761
  • [88] Amperometric glucose biosensors based on composite polymeric structures to prevent interferences
    Mailley, P
    Cosnier, S
    Coche-Guérente, L
    [J]. ANALYTICAL LETTERS, 2000, 33 (09) : 1733 - 1753
  • [89] GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM
    MALITESTA, C
    PALMISANO, F
    TORSI, L
    ZAMBONIN, PG
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (24) : 2735 - 2740
  • [90] Indium tin oxide-coated optical fiber tips for affinity electropolymerization
    Marks, RS
    Novoa, A
    Konry, T
    Krais, R
    Cosnier, S
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2002, 21 (1-2): : 189 - 194