High-resolution blood flow velocity measurements in the human finger

被引:132
作者
Klarhöfer, M
Csapo, B
Balassy, C
Szeles, JC
Moser, E
机构
[1] Univ Vienna, Inst Med Phys, Arbeitsgrp NMR, A-1090 Vienna, Austria
[2] Univ Vienna, Univ Klin Chirurg, Abt Gefasschirurg, A-1090 Vienna, Austria
[3] Univ Vienna, Univ Klin Radiodiagnost, A-1090 Vienna, Austria
关键词
phase contrast; high resolution; blood flow velocity; human finger; 3; Tesla;
D O I
10.1002/mrm.1096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR phase contrast blood flow velocity measurements in the human index finger were performed with triggered, nontriggered, and cine acquisition schemes. A strong (G(max) = 200 mT/m), small bore (inner diameter 12 cm) gradient system inserted in a whole body 3 Tesla MR scanner allowed high-resolution imaging at short echo times, which decreases partial volume effects and flow artifacts. Arterial blood flow velocities ranging from 4.9-19 cm/sec were measured, while venous blood flow was significantly slower at 1.5-7.1 cm/sec. Taking into account the corresponding vessel diameters ranging from 800 mum to 1.8 mm, blood flow rates of 3.0-26 ml/min in arteries and 1.2-4.8 ml/min in veins are obtained. The results were compared to ultrasound measurements, resulting in comparable blood flow velocities in the same subjects. Magn Reson Med 45:716-719, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:716 / 719
页数:4
相关论文
共 21 条
[1]   Valvular function of peripheral veins after hyperemic dilation [J].
Andersson, J ;
Thurin, A ;
Thulesius, O .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (04) :611-615
[2]   FINGERS - 3-DIMENSIONAL MR-IMAGING AND ANGIOGRAPHY WITH A LOCAL GRADIENT COIL [J].
BLACKBAND, SJ ;
CHAKRABARTI, I ;
GIBBS, P ;
BUCKLEY, DL ;
HORSMAN, A .
RADIOLOGY, 1994, 190 (03) :895-899
[3]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[4]   RAPID SCAN MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
HART, HR .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :238-245
[5]   MR IMAGING OF THE FINGER - CORRELATION WITH NORMAL ANATOMIC SECTIONS [J].
ERICKSON, SJ ;
KNEELAND, JB ;
MIDDLETON, WD ;
JESMANOWICZ, A ;
HYDE, J ;
LAWSON, TL ;
FOLEY, WD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) :1013-1019
[6]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[7]   Distal arterial flow in patients undergoing upper extremity dialysis shunting: A prospective study using Doppler sonography [J].
Goldfeld, M ;
Koifman, B ;
Loberant, N ;
Krowll, I ;
Haj, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :513-516
[8]   CORRECTION OF PARTIAL VOLUME INACCURACIES IN QUANTITATIVE PHASE-CONTRAST MR-ANGIOGRAPHY [J].
HAMILTON, CA .
MAGNETIC RESONANCE IMAGING, 1994, 12 (07) :1127-1130
[9]   NONTRIGGERED MAGNETIC-RESONANCE VELOCITY-MEASUREMENT OF THE TIME-AVERAGE OF PULSATILE VELOCITY [J].
HOFMAN, MBM ;
KOUWENHOVEN, M ;
SPRENGER, M ;
VANROSSUM, AC ;
VALK, J ;
WESTERHOF, N .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :648-655
[10]  
Hoogeveen RM, 1999, MAGNET RESON MED, V41, P520, DOI 10.1002/(SICI)1522-2594(199903)41:3<520::AID-MRM14>3.0.CO