Common path Fourier domain optical coherence tomography based on multiple reflections within the sample arm

被引:5
作者
Krstajic, Nikola [1 ]
Hogg, Richard [1 ]
Matcher, Stephen J. [2 ]
机构
[1] Univ Sheffield, Dept Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Dept Mat Sci & Engn, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Biomedical optics; Common path interferometry; Low coherence interferometry; Optical coherence tomography; Fourier domain optical coherence tomography; ULTRAHIGH-RESOLUTION; HIGH-SPEED; INTERFEROMETER; SYSTEM;
D O I
10.1016/j.optcom.2011.02.073
中图分类号
O43 [光学];
学科分类号
070207 [光学];
摘要
We present a common path Fourier domain optical coherence tomography (FDOCT) setup where the reference signal arises from multiple reflections within the sample arm. Two configurations are demonstrated. The first is based on a reflective microscope objective while the second is based on a normal (refractive) microscope objective. The second configuration is effectively a Mireau interferometer. We present a sensitivity analysis of these setups and images of in vivo skin. Advantages of both common path arrangements include: 1) the reference surface is not close to the sample surface while keeping the optical path lengths matched (so the additional interferometer is not needed) and 2) the user can independently control reference and sample arm power. Additionally, the configuration using the refractive objective ensures that the coherence gate and focus gate always match. A disadvantage is that the reference arm power in certain circumstances is not optimal (i.e. close to saturating the CCD). However, this issue can be removed by a light source of sufficient output power. We believe the idea is scalable and therefore of interest to endoscopy applications. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3168 / 3172
页数:5
相关论文
共 36 条
[1]
Aguirre AD, 2008, BIOL MED PHYS BIOMED, P505, DOI 10.1007/978-3-540-77550-8_17
[2]
[Anonymous], 2008, OPTICAL COHERENCE TO
[3]
Dual beam heterodyne Fourier domain optical coherence tomography [J].
Bachmann, Adrian H. ;
Michaely, Roland ;
Lasser, Theo ;
Leitgeb, Rainer A. .
OPTICS EXPRESS, 2007, 15 (15) :9254-9266
[4]
BOER JF, 2008, OPTICAL COHERENCE TO, P147
[5]
Chen Z, 2008, BIOL MED PHYS BIOMED, P621, DOI 10.1007/978-3-540-77550-8_21
[6]
Spectral-domain phase microscopy [J].
Choma, MA ;
Ellerbee, AK ;
Yang, CH ;
Creazzo, TL ;
Izatt, JA .
OPTICS LETTERS, 2005, 30 (10) :1162-1164
[7]
Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[9]
Ultrahigh-resolution optical coherence tomography [J].
Drexler, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :47-74
[10]
Cost effective, all-fiber autocorrelator based 1300 mn OCT system [J].
Feldchtein, F ;
Bush, J ;
Gelikonov, G ;
Gelikonov, V ;
Piyevsky, S .
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 :349-355