Amperometric glucose enzyme electrode by immobilizing glucose oxidase in multilayers on self-assembled monolayers surface

被引:40
作者
Hou, SF [1 ]
Yang, KS [1 ]
Fang, HQ [1 ]
Chen, HY [1 ]
机构
[1] Nanjing Univ, State Key Lab Coordinat Chem, Dept Chem, Nanjing 210093, Peoples R China
基金
中国国家自然科学基金;
关键词
multilayer film; glucose oxidase; self-assembled monolayers; Os(bpy)(2)Cl-PVP complex;
D O I
10.1016/S0039-9140(98)00081-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and robust amperometric enzyme electrode for the determination of glucose was constructed by immobilizing glucose oxidase (GOD) and Os(bpy)(2)Cl-poly(4-vinyl)pyridine (Os-PVP) complex multilayers on thiol self-assembled monolayers surface. The apparent Michaelis-Menton constant K-m' increased with increasing the number of Os-PVP/GOD multilayers. The concentration range of linear response and detection limit were 0.1-10 and 0.05 mM, the interference of ascorbic acid and uric acid were eliminated by the presence of SAMs and the enzyme electrodes were stable over 3 weeks. The preparation technique may be useful for controlling the performance of multilayer enzyme electrodes by changing the enzyme content. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:561 / 567
页数:7
相关论文
共 19 条
  • [1] STEP-BY-STEP IMMUNOLOGICAL CONSTRUCTION OF A FULLY ACTIVE MULTILAYER ENZYME ELECTRODE
    BOURDILLON, C
    DEMAILLE, C
    MOIROUX, J
    SAVEANT, JM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (22) : 10328 - 10329
  • [2] GASS AEG, 1984, ANAL CHEM, V56, P667
  • [3] A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER
    GORTON, L
    KARAN, HI
    HALE, PD
    INAGAKI, T
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 23 - 30
  • [4] CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS
    GREGG, BA
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 258 - 263
  • [5] AMPEROMETRIC GLUCOSE BIOSENSORS BASED ON REDOX POLYMER-MEDIATED ELECTRON-TRANSFER
    HALE, PD
    BOGUSLAVSKY, LI
    INAGAKI, T
    KARAN, HI
    LEE, HS
    SKOTHEIM, TA
    OKAMOTO, Y
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (07) : 677 - 682
  • [6] ELECTROCHEMICAL DEPOSITION OF AVIDIN ON THE SURFACE OF A PLATINUM-ELECTRODE FOR ENZYME SENSOR APPLICATIONS
    HOSHI, T
    ANZAI, J
    OSA, T
    [J]. ANALYTICA CHIMICA ACTA, 1994, 289 (03) : 321 - 327
  • [7] IMMOBILIZED ENZYME CHEMICALLY MODIFIED ELECTRODE AS AN AMPEROMETRIC SENSOR
    IANNIELLO, RM
    YACYNYCH, AM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (13) : 2090 - 2095
  • [8] FERROCENE-ATTACHED L-LYSINE POLYMERS AS MEDIATORS FOR GLUCOSE-SENSING ELECTRODES
    IIJIMA, S
    MIZUTANI, F
    YABUKI, S
    TANAKA, Y
    ASAI, M
    KATSURA, T
    HOSAKA, S
    IBONAI, M
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 483 - 487
  • [9] JONSSON G, 1987, ANAL LETT, V20, P839
  • [10] KELEINFELD E, 1994, SCIENCE, V265, P370