共 33 条
Development of a Protein Standard Absolute Quantification (PSAQ™) assay for the quantification of Staphylococcus aureus enterotoxin A in serum
被引:31
作者:
Adrait, Annie
[1
,2
,3
]
Lebert, Dorothee
[1
,2
,3
,4
]
Trauchessec, Mathieu
[1
,2
,3
]
Dupuis, Alain
[1
,2
,3
]
Louwagie, Mathilde
[1
,2
,3
]
Masselon, Christophe
[1
,2
,3
]
Jaquinod, Michel
[1
,2
,3
]
Chevalier, Benoit
[5
]
Vandenesch, Francois
[6
,7
]
Garin, Jerome
[1
,2
,3
]
Bruley, Christophe
[1
,2
,3
]
Brun, Virginie
[1
,2
,3
,4
]
机构:
[1] CEA, IRTSV, F-38054 Grenoble, France
[2] INSERM, U1038, F-38054 Grenoble, France
[3] Univ Grenoble 1, F-38000 Grenoble, France
[4] Promise Adv Prote, F-38040 Grenoble, France
[5] Hop Instruct Armees Desgenettes, F-69003 Lyon, France
[6] INSERM, U851, F-69008 Lyon, France
[7] Univ Lyon, Fac Med Laennec, F-69008 Lyon, France
基金:
欧盟第七框架计划;
关键词:
Absolute quantification;
PSAQ;
Mass spectrometry;
SRM;
Enterotoxin;
Sepsis;
TANDEM MASS-SPECTROMETRY;
SEPTIC SHOCK;
ISOTOPE-DILUTION;
DOPING CONTROL;
EQUINE PLASMA;
PROTEOMICS;
SUPERANTIGEN;
BIOMARKERS;
ANTIBODY;
PEPTIDE;
D O I:
10.1016/j.jprot.2011.11.031
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Enterotoxin A (SEA) is a staphylococcal virulence factor which is suspected to worsen septic shock prognosis. However, the presence of SEA in the blood of sepsis patients has never been demonstrated. We have developed a mass spectrometry-based assay for the targeted and absolute quantification of SEA in serum. To enhance sensitivity and specificity, we combined an immunoaffinity-based sample preparation with mass spectrometry analysis in the selected reaction monitoring (SRM) mode. Absolute quantification of SEA was performed using the PSAQ (TM) method (Protein Standard Absolute Quantification), which uses a full-length isotope-labeled SEA as internal standard. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) were estimated at 352 pg/mL and 1057 pg/mL, respectively. SEA recovery after immunocapture was determined to be 7.8 +/- 1.4%. Therefore, we assumed that less than 1 femtomole of each SEA proteotypic peptide was injected on the liquid chromatography column before SRM analysis. From a 6-point titration experiment, quantification accuracy was determined to be 77% and precision at LLOQ was lower than 5%. With this sensitive PSAQ-SRM assay, we expect to contribute to decipher the pathophysiological role of SEA in severe sepsis. This article is part of a Special Issue entitled: Proteomics: The clinical link. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3041 / 3049
页数:9
相关论文