Extending the longevity of fluorescence-based sensor arrays using adaptive exposure

被引:29
作者
Bencic-Nagale, S [1 ]
Walt, DR [1 ]
机构
[1] Tufts Univ, Dept Chem, Medford, MA 02155 USA
关键词
D O I
10.1021/ac0505021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescent microbead sensor arrays were prepared to determine sensor array longevity. Sensor longevity is limited by photobleaching of the dyes attached to the microbeads and presents one of the biggest drawbacks of most fluorescent dye-based arrays. Responses of an array of organic vapor sensors were acquired for 2 weeks to evaluate the sensor performance over time. Photobleaching effects were overcome in two ways: (1) by limiting the excitation light power and gradually increasing the power at a rate comparable to the sensor photobleaching rates and (2) by illuminating subsections of the array through an optical slit. Both approaches extended the longevity of a sensor array. During the longevity study, the sensor arrays were employed to test their ability to correctly distinguish between responses to seven vapors. A high classification accuracy (99.8%) was obtained after 17 700 exposures for vapor responses collected over two weeks using only similar to 8% of the array's surface area.
引用
收藏
页码:6155 / 6162
页数:8
相关论文
共 34 条
  • [1] AGAYN V, 1993, IMMUNOMETHODS, V3, P112
  • [2] Cross-reactive chemical sensor arrays
    Albert, KJ
    Lewis, NS
    Schauer, CL
    Sotzing, GA
    Stitzel, SE
    Vaid, TP
    Walt, DR
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2595 - 2626
  • [3] Information coding in artificial olfaction multisensor arrays
    Albert, KJ
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (16) : 4161 - 4167
  • [4] Field-deployable sniffer for 2,4-dinitrotoluene detection
    Albert, KJ
    Myrick, ML
    Brown, SB
    James, DL
    Milanovich, FP
    Walt, DR
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) : 3193 - 3200
  • [5] Optical multibead arrays for simple and complex odor discrimination
    Albert, KJ
    Walt, DR
    Gill, DS
    Pearce, TC
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (11) : 2501 - 2508
  • [6] High-speed fluorescence detection of explosives-like vapors
    Albert, KJ
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (09) : 1947 - 1955
  • [7] CHEMICAL SENSORS BASED ON CONTROLLED-RELEASE POLYMER SYSTEMS
    BARNARD, SM
    WALT, DR
    [J]. SCIENCE, 1991, 251 (4996) : 927 - 929
  • [8] Increasing lifetimes of fiber-optic sensor arrays for chemical warfare detection
    Bencic, S
    Walt, DR
    [J]. CHEMICAL AND BIOLOGICAL POINT SENSORS FOR HOMELAND DEFENSE, 2004, 5269 : 83 - 88
  • [9] Berrios M, 1999, METHOD ENZYMOL, V307, P55
  • [10] NEAREST NEIGHBOR PATTERN CLASSIFICATION
    COVER, TM
    HART, PE
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 1967, 13 (01) : 21 - +