Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma

被引:101
作者
Gellekink, H
Van Oppenraaij-Emmerzaal, D
van Rooij, A
Struys, EA
den Heijer, M
Blom, HJ
机构
[1] Radboud Univ Nijmegen, Lab Pediat & Neurol 424, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Endocrinol 531, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Dept Epidemiol & Biostat, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[4] Vrije Univ Amsterdam, Med Ctr, Dept Clin Chem, Metab Unit, Amsterdam, Netherlands
关键词
D O I
10.1373/clinchem.2004.046995
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet). Methods: We used stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry (LC-ESI-MS/MS) to measure AdoMet and AdoHcy in plasma. Acetic acid was added to prevent AdoMet degradation. Solid-phase extraction (SPE) columns containing phenylboronic acid were used to bind AdoMet, AdoHcy, and their internal standards and for sample cleanup. An HPLC C-18 column directly coupled to the LC-MS/MS was used for separation and detection. Results: In plasma samples, the interassay CVs for AdoMet and AdoHcy were 3.9% and 8.3%, and the intraassay CVs were 4.2% and 6.7%, respectively. Mean recoveries were 94.5% for AdoMet and 96.8% for AdoHcy. The quantification limits were 2.0 and 1.0 nmol/L for AdoMet and AdoHcy, respectively. Immediate acidification of the plasma samples with acetic acid prevented the observed AdoMet degradation. In a group of controls (mean plasma total Hcy, 11.2 mu mol/L), plasma AdoMet and AdoHcy were 94.5 and 12.3 nmol/L, respectively. Conclusions: Stable-isotope dilution LC-ESI-MS/MS allows sensitive and rapid measurement of AdoMet and AdoHcy. The SPE columns enable simple cleanup, and no metabolite derivatization is needed. The instability of AdoMet is a serious problem and can be prevented easily by immediate acidification of samples. (c) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:1487 / 1492
页数:6
相关论文
共 17 条
[1]   Measurement of plasma S-adenosylmethionine and S-adenosylhomocysteine as their fluorescent isoindoles [J].
Capdevila, A ;
Wagner, C .
ANALYTICAL BIOCHEMISTRY, 1998, 264 (02) :180-184
[2]   Increased, homocysteine and S-adenosylhomocysteine concentrations and DNA hypomethylation in vascular disease [J].
Castro, R ;
Rivera, I ;
Struys, EA ;
Jansen, EEW ;
Ravasco, P ;
Camilo, ME ;
Blom, HJ ;
Jakobs, C ;
de Almeida, IT .
CLINICAL CHEMISTRY, 2003, 49 (08) :1292-1296
[3]   Elevation in S-adenosylhomocysteine and DNA hypomethylation:: Potential epigenetic mechanism for homocysteine-related pathology [J].
James, SJ ;
Melnyk, S ;
Pogribna, M ;
Pogribny, IP ;
Caudill, MA .
JOURNAL OF NUTRITION, 2002, 132 (08) :2361S-2366S
[4]  
Kerins DM, 2001, AM J CLIN NUTR, V74, P723
[5]   Disturbed ratio of erythrocyte and plasma S-adenosylmethionine/S-adenosylhomocysteine in peripheral arterial occlusive disease [J].
Loehrer, FMT ;
Tschöpl, M ;
Angst, CP ;
Litynski, P ;
Jäger, K ;
Fowler, B ;
Haefeli, WE .
ATHEROSCLEROSIS, 2001, 154 (01) :147-154
[6]   Effect of methionine loading on 5-methyltetrahydrofolate, S-adenosylmethionine and S-adenosylhomocysteine in plasma of healthy [J].
Loehrer, FMT ;
Haefei, WE ;
Angst, CP ;
Browne, G ;
Frick, G ;
Fowler, B .
CLINICAL SCIENCE, 1996, 91 (01) :79-86
[7]   Evidence for disturbed S-adenosylmethionine:S-adenosylhomocysteine ratio in patients with end-stage renal failure:: A cause for disturbed methylation reactions? [J].
Loehrer, FMT ;
Angst, CP ;
Brunner, FP ;
Haefeli, WE ;
Fowler, B .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (03) :656-661
[8]   Simultaneous determination of adenosine, S-adenosylhomocysteine and S-adenosylmethionine in biological samples using solid-phase extraction and high-performance liquid chromatography [J].
Luippold, G ;
Delabar, U ;
Kloor, D ;
Mühlbauer, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 724 (02) :231-238
[9]   Methylation and acetylation in nervous system development and neurodegenerative disorders [J].
Mattson, MP .
AGEING RESEARCH REVIEWS, 2003, 2 (03) :329-342
[10]  
Melnyk S, 2000, CLIN CHEM, V46, P265