Ultra high performance liquid chromatography-atmospheric pressure photoionization-mass spectrometry for high-sensitivity analysis of US Environmental Protection Agency sixteen priority pollutant polynuclear aromatic hydrocarbons in oysters

被引:46
作者
Cai, Sheng-Suan [1 ]
Stevens, Joan [2 ]
Syage, Jack A. [1 ]
机构
[1] Syagen Technol Inc, Tustin, CA 92780 USA
[2] Agilent Technol, Santa Clara, CA 95051 USA
关键词
Ultra high performance liquid chromatography (UHPLC); Atmospheric pressure photoionization (APPI); Mass spectrometry (MS); Polynuclear aromatic hydrocarbon (PAH); Oyster; CHARGE-EXCHANGE IONIZATION; ELECTROSPRAY-IONIZATION; NONPOLAR COMPOUNDS; LIPIDS; QUANTIFICATION; PEPTIDES; DOPANTS; LC/MS; MS/MS;
D O I
10.1016/j.chroma.2011.12.111
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
In response to Gulf of Mexico deepwater horizon oil spill, we have developed an atmospheric pressure photoionization (APPI) based ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) method for high-sensitivity analysis of United States Environmental Protection Agency (US EPA) 16 priority pollutant polynuclear aromatic hydrocarbons (PAHs) in oysters. Analyses were performed on an Agilent's Infinity 1290 UHPLC system coupled with a G6140A single quadrupole MS detector with Syagen's PhotoMate (R) APPI (R) source. Column separation was achieved using Zorbax Eclipse PAH column. Chlorobenzene was used as an APPI dopant for maximum overall sensitivity. Dynamic linear ranges were evaluated and found to cover 3.6-5.1 (Ave. 4.4) orders of magnitude with R-2 of at least 0.995. A quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and cleanup procedure was used. The spike recoveries ranged from 77% to 110% with %RSD of 0.6-6.7 at spike concentrations below or substantially below the US Food and Drug Administration (FDA) level of concern in oysters. The on-column instrument detection limits (IDLs, 6 sigma S/N = 3) ranged from 8 to 106 pg with an average of 23 pg for 16 PAHs. The method detection limits (MDLs, 6 sigma S/N = 3) ranged from 0.013 to 0.129 ppm with an average of 0.040 ppm for all analytes. These MDLs were about 5 times to over 4 orders of magnitude lower than US FDA levels of concern in oysters. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 29 条
[1]
Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 [J].
Adamec, Jiri ;
Jannasch, Amber ;
Huang, Jianjie ;
Hohman, Emily ;
Fleet, James C. ;
Peacock, Munro ;
Ferruzzi, Mario G. ;
Martin, Berdine ;
Weaver, Connie M. .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) :11-20
[2]
Atmospheric pressure photoionization of peptides [J].
Bagag, A. ;
Giuliani, A. ;
Laprevote, O. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 299 (01) :1-4
[3]
Liquid chromatography-atmospheric pressure photoionization-mass spectrometry analysis of triacylglycerol lipids - Effects of mobile phases on sensitivity [J].
Cai, Sheng-Suan ;
Short, Luke Chandler ;
Syage, Jack A. ;
Potvin, Michael ;
Curtis, Jonathan M. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) :88-97
[4]
Ultra Performance Liquid Chromatography-Atmospheric Pressure Photoionization-Tandem Mass Spectrometry for High-Sensitivity and High-Throughput Analysis of US Environmental Protection Agency 16 Priority Pollutants Polynuclear Aromatic Hydrocarbons [J].
Cai, Sheng-Suan ;
Syage, Jack A. ;
Hanold, Karl A. ;
Balogh, Michael P. .
ANALYTICAL CHEMISTRY, 2009, 81 (06) :2123-2128
[5]
Atmospheric pressure photoionization mass spectrometry for analysis of fatty acid and acylglycerol lipids [J].
Cai, SS ;
Syage, JA .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1110 (1-2) :15-26
[6]
Comparison of atmospheric pressure photoionization, atmospheric pressure chemical ionization, and electrospray ionization mass spectrometry for analysis of lipids [J].
Cai, SS ;
Syage, JA .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1191-1199
[7]
Fragmentation induced in atmospheric pressure photoionization of peptides [J].
Debois, D. ;
Giuliani, A. ;
Laprevote, O. .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (12) :1554-1560
[8]
Gratz S., SCREEN PRESENCE POLY
[9]
A new quantitative LC tandem mass spectrometry assay for serum 25-hydroxy vitamin D [J].
Herrmann, Markus ;
Harwood, Tim ;
Gaston-Parry, Olivia ;
Kouzios, Dorothy ;
Wong, Tang ;
Lih, Anna ;
Jimenez, Mark ;
Janu, Margaret ;
Seibel, Markus J. .
STEROIDS, 2010, 75 (13-14) :1106-1112
[10]
Characterizing Photochemical Transformation of Aqueous nC60 under Environmentally Relevant Conditions [J].
Hwang, Yu Sik ;
Li, Qilin .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (08) :3008-3013