2D-3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models

被引:135
作者
Baka, N. [1 ,2 ,3 ]
Kaptein, B. L. [4 ]
de Bruijne, M. [2 ,3 ,5 ]
van Walsum, T. [2 ,3 ]
Giphart, J. E. [6 ]
Niessen, W. J. [2 ,3 ,7 ]
Lelieveldt, B. P. F. [1 ,8 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2333 ZA Leiden, Netherlands
[2] Erasmus MC, Dept Radiol, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[3] Erasmus MC, Dept Med Informat, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[4] Leiden Univ, Med Ctr, Dept Orthopaed, NL-2333 ZA Leiden, Netherlands
[5] Univ Copenhagen, Dept Comp Sci, DK-1168 Copenhagen, Denmark
[6] Steadman Philippon Res Inst, Biomech Res Dept, Vail, CO USA
[7] Delft Univ Technol, Dept Appl Sci, NL-2600 AA Delft, Netherlands
[8] Delft Univ Technol, Dept Mediamat, NL-2600 AA Delft, Netherlands
关键词
SSM; PDM; 3D-2D non-rigid registration; Biplane fluoroscopy; Edge selection; 3D RECONSTRUCTION; ARTHROPLASTY; NAVIGATION; ATLAS; RSA;
D O I
10.1016/j.media.2011.04.001
中图分类号
TP18 [人工智能理论];
学科分类号
140502 [人工智能];
摘要
Three-dimensional patient specific bone models are required in a range of medical applications, such as pre-operative surgery planning and improved guidance during surgery, modeling and simulation, and in vivo bone motion tracking. Shape reconstruction from a small number of X-ray images is desired as it lowers both the acquisition costs and the radiation dose compared to CT. We propose a method for pose estimation and shape reconstruction of 3D bone surfaces from two (or more) calibrated X-ray images using a statistical shape model (SSM). User interaction is limited to manual initialization of the mean shape. The proposed method combines a 3D distance based objective function with automatic edge selection on a Canny edge map. Landmark-edge correspondences are weighted based on the orientation difference of the projected silhouette and the corresponding image edge. The method was evaluated by rigid pose estimation of ground truth shapes as well as 3D shape estimation using a SSM of the whole femur, from stereo cadaver X-rays, in vivo biplane fluoroscopy image-pairs, and an in vivo biplane fluoroscopic sequence. Ground truth shapes for all experiments were available in the form of CT segmentations. Rigid registration of the ground truth shape to the biplane fluoroscopy achieved sub-millimeter accuracy (0.68 mm) measured as root mean squared (RMS) point-to-surface (P2S) distance. The non-rigid reconstruction from the biplane fluoroscopy using the SSM also showed promising results (1.68 mm RMS P2S). A feasibility study on one fluoroscopic time series illustrates the potential of the method for motion and shape estimation from fluoroscopic sequences with minimal user interaction. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:840 / 850
页数:11
相关论文
共 28 条
[1]
3D/2D registration and segmentation of scoliotic vertebrae using statistical models [J].
Benameur, S ;
Mignotte, M ;
Parent, S ;
Labelle, H ;
Skalli, W ;
de Guise, J .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (05) :321-337
[2]
TRAINABLE METHOD OF PARAMETRIC SHAPE-DESCRIPTION [J].
COOTES, TF ;
COOPER, DH ;
TAYLOR, CJ ;
GRAHAM, J .
IMAGE AND VISION COMPUTING, 1992, 10 (05) :289-294
[3]
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics [J].
Dennis, DA ;
Mahfouz, MR ;
Komistek, RD ;
Hoff, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :241-253
[4]
Dworzak J., 2010, INT J COMPUTER ASSIS
[5]
FELDMAR J, 1995, FIFTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, PROCEEDINGS, P549, DOI 10.1109/ICCV.1995.466891
[6]
GAMEs: Growing and adaptive meshes for fully automatic shape modeling and analysis [J].
Ferrarini, Luca ;
Olofsen, Hans ;
Palm, Walter M. ;
van Buchem, Mark A. ;
Reiber, Johan H. C. ;
Admiraal-Behloul, Faiza .
MEDICAL IMAGE ANALYSIS, 2007, 11 (03) :302-314
[7]
Fleute M, 1999, LECT NOTES COMPUT SC, V1679, P138
[8]
Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study [J].
Hart, Radek ;
Svab, Pavel ;
Filan, Peter .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) :429-434
[9]
Registration of a CT-like atlas to fluoroscopic X-ray images using intensity correspondences [J].
Hurvitz, Aviv ;
Joskowicz, Leo .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (06) :493-504
[10]
Fast alignment of 3D geometrical models and 2D color images using 2D distance maps [J].
Iwashita, Y ;
Kurazume, R ;
Hasegawa, T ;
Hara, K .
FIFTH INTERNATIONAL CONFERENCE ON 3-D DIGITAL IMAGING AND MODELING, PROCEEDINGS, 2005, :164-171