Reagentless system for sulphite determination based on polyaniline

被引:20
作者
de Marcos, S [1 ]
Alcubierre, N [1 ]
Galbán, J [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, Analyt Spect & Sensors Grp GEAS, E-5009 Zaragoza, Spain
关键词
reagentless system; polyaniline; sulphite; wine; molecular absorption spectrometry;
D O I
10.1016/j.aca.2003.09.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new reagentless system for sulphite (or sulphur dioxide) determination is reported based on the use of an organic conducting polymer, polyaniline, and its absorbance variation at 550 m, depending on the sulphite concentration. After chemical polymerisation of aniline a very thin film of polyaniline is obtained. Although the response is not fully reversible, each film can be used for at least 10 measurements for low analyte concentrations (up to 0.5 mg l(-1)) and five measurements for higher sulphite concentrations. Moreover, the reproducibility, ease of preparation and low cost of the films, permit the use of a new disposable system for each measurement. When the change in absorbance at 550 nm was measured for 210 s (stabilisation time), the system showed a linear response, which ranged from 0.025 to 1.50 mg l(-1) of sulphite. A theory with regard to the reaction mechanism between the polyaniline films and sulphite is also proposed. The system was applied to sulphite determination in wine samples and the results were in agreement with those obtained by the Official Method of Analysis (iodometric titration). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 34 条
[1]  
ABSELGHANI A, 2001, SENSOR ACTUAT B-CHEM, V74, P17
[2]   Toward a method for measuring oxygen transfer in biofilters [J].
Amiel, C ;
Gillot, S ;
Roustan, M ;
Héduit, EA .
WATER QUALITY RESEARCH JOURNAL OF CANADA, 2002, 37 (04) :729-743
[3]   A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use [J].
Andreou, VG ;
Clonis, YD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :61-69
[4]   An assay for ascorbic acid based on polyaniline-coated microplates [J].
Bossi, A ;
Piletsky, SA ;
Piletska, EV ;
Righetti, PG ;
Turner, APF .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4296-4300
[5]  
Daunoravicius Z, 2002, ELECTROPHORESIS, V23, P2439, DOI 10.1002/1522-2683(200208)23:15<2439::AID-ELPS2439>3.0.CO
[6]  
2-Z
[7]   Determination of sulphite in wines by gas-diffusion flow injection analysis utilizing spectrophotometric pH-detection [J].
DecnopWeever, LG ;
Kraak, JC .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :125-131
[8]   Optical sensing of pH based on polypyrrole films [J].
deMarcos, S ;
Wolfbeis, OS .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :149-153
[9]  
deMarcos S, 1997, SENSOR MATER, V9, P253
[10]   Development and calibration of field-effect transistor-based sensor array for measurement of hydrogen and ammonia gas mixtures in humid air [J].
Domansky, K ;
Baldwin, DL ;
Grate, JW ;
Hall, TB ;
Li, J ;
Josowicz, M ;
Janata, J .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :473-481