The Oxford medial unicompartmental arthroplasty - A ten-year survival study

被引:536
作者
Murray, DW [1 ]
Goodfellow, JW [1 ]
O'Connor, JJ [1 ]
机构
[1] Nuffield Orthopaed Ctr, Oxford Orthopaed Engn Ctr, Oxford OX3 7LD, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1998年 / 80B卷 / 06期
关键词
D O I
10.1302/0301-620X.80B6.8177
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the 'worst-case' survival rate was 97%, No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The ten-year survival rate is the best of those reported for unicompartmental arthroplasty and not significantly different from the best rates for total knee replacement.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 50 条
[1]  
Ahlback S., 1968, Acta Radiol Diagn (Stockh), V277, P7
[2]  
[Anonymous], 1995, The Knee, DOI 10.1016/0968-0160(95)00017-J
[3]  
[Anonymous], DOSIMETRY IONIZING R
[4]   St. Georg sledge for medial compartment knee replacement - 461 arthroplasties followed for 4 (1-17) years [J].
Ansari, S ;
Newman, JH ;
Ackroyd, CE .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (05) :430-434
[5]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[6]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[7]  
BARTLEY RE, 1994, CLIN ORTHOP RELAT R, V299, P18
[8]  
BEUCHEL FF, 1990, CLIN ORTHOP RELAT R, V260, P162
[9]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[10]  
Capra S W Jr, 1992, J Arthroplasty, V7, P247, DOI 10.1016/0883-5403(92)90044-Q