A device for in vivo measurements of quantitative ultrasound variables at the human proximal femur

被引:36
作者
Barkmann, Reinhard [1 ]
Laugier, Pascal [2 ]
Moser, Urs [3 ]
Dencks, Stefanie [1 ]
Klausner, Michael [4 ]
Padilla, Frederic [2 ]
Haiat, Guilleaume [5 ]
Glueer, Claus-C. [1 ]
机构
[1] Univ Klinikum Schleswig Holstein, Dept Diagnost Radiol, Med Phys Res Grp, Kiel, Germany
[2] Univ Paris 06, Natl Ctr Sci Res, Lab Imagerie Parametr, Paris, France
[3] Sulzer Innotec, Winterthur, Switzerland
[4] FB Maschinenwesen, Fachhsch Kiel, Kiel, Germany
[5] Univ Paris 12, Natl Ctr Sci Res, UMR, Mecan Phys Lab, Creteil, France
关键词
D O I
10.1109/TUFFC.2008.783
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitative ultrasound (QUS) at the calcaneus has similar power as a bone mineral density (BMD)- measurement using DXA for the prediction of osteoporotic fracture risk. Ultrasound equipment is less expensive than DXA and free of ionizing radiation. As a mechanical wave, QUS has the potential of measuring different bone properties than dual X-ray absorptiometry (DXA,) which depends on X-ray attenuation and might be developed into a tool of comprehensive assessment of bone strength. However, sitespecific DXA at the proximal femur shows best performance in the prediction of hip fractures. To combine the potential of QUS with measurements directly at the femur, we developed a device for in vivo QUS measurements at this site. Methods comprise ultrasound transmission through the bone, reflection from the bone surface, and backscatter from the inner trabecular structure. The complete area of the proximal femur can be scanned except at the femoral head, which interferes with the ilium. To avoid edge artifacts, a subregion of the proximal femur in the trochanteric region was selected as measurement region. First, in vivo measurements demonstrate a good signal to noise ratio and proper depiction of the proximal femur on an attenuation image. Our results demonstrate the feasibility of in vivo measurements. Further improvements can be expected by refinement of the scanning technique and data evaluation method to enhance the potential of the new method for the estimation of bone strength. © 2006 IEEE.
引用
收藏
页码:1197 / 1204
页数:8
相关论文
共 18 条
[11]   In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements:: Relationships to bone mineral density [J].
Jenson, F ;
Padilla, F ;
Bousson, V ;
Bergot, C ;
Laredo, JD ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (01) :654-663
[12]   Predictive value of BMD for hip and other fractures [J].
Johnell, O ;
Kanis, JA ;
Oden, A ;
Johansson, H ;
De Laet, C ;
Delmas, P ;
Eisman, JA ;
Fujiwara, S ;
Kroger, H ;
Mellstrom, D ;
Meunier, PJ ;
Melton, LJ ;
O'Neill, T ;
Pols, H ;
Reeve, J ;
Silman, A ;
Tenenhouse, A .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (07) :1185-1194
[13]   An update on the diagnosis and assessment of osteoporosis with densitometry [J].
Kanis, JA ;
Glüer, CC .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (03) :192-202
[14]   Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures [J].
Marshall, D ;
Johnell, O ;
Wedel, H .
BRITISH MEDICAL JOURNAL, 1996, 312 (7041) :1254-1259
[15]   Anomalous negative dispersion in bone can result from the interference of fast and slow waves [J].
Marutyan, Karen R. ;
Holland, Mark R. ;
Miller, James G. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (05) :EL55-EL61
[16]   Guided ultrasonic waves in long bones:: modelling, experiment and in vivo application [J].
Nicholson, PHF ;
Moilanen, P ;
Kärkkäinen, T ;
Timonen, J ;
Cheng, SL .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (04) :755-768
[17]  
Njeh C, 1999, Quantitative Ultrasound. Assessment of Osteoporosis and Bone Status
[18]   In vitro ultrasound measurement at the human femur [J].
Padilla, F ;
Akrout, L ;
Kolta, S ;
Latremouille, C ;
Roux, C ;
Laugier, P .
CALCIFIED TISSUE INTERNATIONAL, 2004, 75 (05) :421-430