A CVD-diamond based beam profile monitor for undulator radiation

被引:24
作者
Schulze-Briese, C
Ketterer, B
Pradervand, C
Brönnimann, C
David, C
Horisberger, R
Puig-Molina, A
Graafsma, H
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
synchrotron radiation; beam profile monitor; CVD-diamond; automatic beamline alignment;
D O I
10.1016/S0168-9002(01)00281-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
First results obtained with prototypes of a new type of beam profile monitor based on semi-transparent CVD-diamond are presented. The devices consists of a few micrometer thin membrane on a Si-substrate. Ti/Al-pixel are generated lithographically on-the membrane while the signal wires are deposited on a dielectric in order to minimise signal pickup. Synchrotron radiation tests at 8 keV showed good signal homogeneity, spatial resolution and linearity for low resistivity diamond membranes. Considerable difficulties were encountered in the test of a detector grade diamond membrane. They are most likely related to enhanced surface conductivity and capacitive effects. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:230 / 234
页数:5
相关论文
共 6 条
[1]   Diamond-based semi-transparent beam-position monitor for synchrotron radiation applications [J].
Bergonzo, P ;
Brambilla, A ;
Tromson, D ;
Marshall, RD ;
Jany, C ;
Foulon, F ;
Gauthier, C ;
Solé, VA ;
Rogalev, A ;
Goulon, J .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :1-5
[2]  
HAENNI W, 2000, COMMUNICATION
[3]   A NOVEL READOUT CHIP FOR SILICON STRIP DETECTORS WITH ANALOG PIPELINE AND DIGITALLY CONTROLLED ANALOG SIGNAL-PROCESSING [J].
HORISBERGER, R ;
PITZL, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :92-99
[4]   Origin of surface conductivity in diamond [J].
Maier, F ;
Riedel, M ;
Mantel, B ;
Ristein, J ;
Ley, L .
PHYSICAL REVIEW LETTERS, 2000, 85 (16) :3472-3475
[5]   Diamond beam-position monitor for undulator radiation and tests at the Tristan super light facility [J].
Sakae, H ;
Aoyagi, H ;
Oura, M ;
Kimura, H ;
Ohata, T ;
Shiwaku, H ;
Yamamoto, S ;
Sugiyama, H ;
Tanabe, K ;
Kobashi, K ;
Kitamura, H .
JOURNAL OF SYNCHROTRON RADIATION, 1997, 4 :204-209
[6]   Synthetic diamond-based position-sensitive photoconductive detector development for the Advanced Photon Source [J].
Shu, DM ;
Kuzay, TM ;
Fang, Y ;
Barraza, J ;
Cundiff, T .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :636-638