The clinical relevance of hip joint simulator testing: In vitro and in vivo comparisons

被引:40
作者
Essner, A [1 ]
Schmidig, G [1 ]
Wang, A [1 ]
机构
[1] Stryker Orthopaed, Mahwah, NJ 07430 USA
关键词
hip simulator; UHMWPE wear; clinical validation; total hip replacement;
D O I
10.1016/j.wear.2005.02.105
中图分类号
TH [机械、仪表工业];
学科分类号
0802 [机械工程];
摘要
Hip joint simulators are widely used for evaluation of new bearing designs and materials. Although test methodology has been refined and accuracy improved over time, establishing clinical relevance remains the ultimate goal of this testing. Three criteria were set to establish clinical validation; simulator wear rates, qualitative and quantitative wear rate rankings and wear debris morphology. All must duplicate those reported clinically. Several material models with known and published clinical performance can be used to validate any hip simulator and test methodology. These include polytetrafluoroethylene (PTFE) versus ultra-high molecular weight polyethylene (UHMWPE) (or the Charnley model), Hylamer((R)) versus conventional UHMWPE and ethylene oxide (EtO) or gas plasma sterilized UHMWPE versus gamma-irradiated in air UHMWPE. Studies on these materials are retrospective, however, a fourth model involving Duration((R)) stabilized UHMWPE versus gamma-irradiated in air UHMWPE was used prospectively. Generic or commercially available acetabular liners of these materials were fabricated or obtained and tested in a multi station hip simulator under physiologic loading, cross-path motion, anatomical positioning and biological lubrication conditions. All liners were articulated with CoCr femoral heads (R-a = 0.02 mu m). Literature reported clinical wear rates and wear rate ratios were precisely reproduced for the retrospective models. Methodology was found to have significant influence. Clinical performance of the fourth material model was first predicted and then corroborated. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:882 / 886
页数:5
相关论文
共 15 条
[1]
CHANDLER HP, 1996, 26 ANN HARR COURS TH
[2]
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, P170
[3]
OPTIMUM SIZE OF PROSTHETIC HEADS IN RELATION TO WEAR OF PLASTIC SOCKETS IN TOTAL REPLACEMENT OF HIP [J].
CHARNLEY, J ;
KAMANGAR, A ;
LONGFIELD, MD .
MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01) :31-+
[4]
Increase in early polyethylene wear after sterilization with ethylene oxide -: Radiostereometric analyses of 201 total hips [J].
Digas, G ;
Thanner, J ;
Nivbrant, B ;
Röhrl, S ;
Ström, H ;
Kärrholm, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (05) :531-541
[5]
DUMBLETON JH, 1981, TRIBOLOGY NATURE ART
[6]
GRIFFITH MJ, 1978, CLIN ORTHOP RELAT R, P37
[7]
Effect of terminal sterilization with gas plasma or gamma radiation on wear of polyethylene liners [J].
Hopper, RH ;
Young, AM ;
Orishimo, KF ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :464-468
[8]
LENTNER C, 1981, GEIGY SCI TABLES, V1, P161
[9]
Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner [J].
Livingston, BJ ;
Chmell, MJ ;
Spector, M ;
Poss, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1529-1538
[10]
LIVINGSTON BJ, 1997, 43 ANN M ORS SAN FRA, P141