Spectroscopic and imaging capabilities of a pixellated photon counting system

被引:7
作者
Amendolia, SR
Bisogni, MG
Bottigli, U
Delogu, P
Dipasquale, G
Fantacci, ME
Marchi, A
Marzulli, VM
Oliva, P
Palmiero, R
Rosso, V
Stefanini, A
Stumbo, S
Zucca, S
机构
[1] Univ Pisa, Dipartimento Fis, I-56010 Pisa, Italy
[2] Ist Nazl Fis Nucl, Sez Pisa, I-56010 Pisa, Italy
[3] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[4] Univ Sassari, Ist Matemat & Fis, I-07100 Sassari, Italy
关键词
GaAs pixel detector; photon counting chip; medical imaging;
D O I
10.1016/S0168-9002(01)00827-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We are studying the performance of various thickness GaAs pixel detectors bump-bonded to a dedicated photon counting chip (PCC) for medical imaging applications in different energy ranges. In this work we present the experimental results obtained with a 600 mum thick pixel matrix (64 x 64 square pixels, 170 mum side) in the 60-140 keV energy range to evaluate the possible use of such a system in the nuclear medicine field. In particular, we have measured the spectroscopic properties of the detector (charge collection efficiency, energy resolution and detection efficiency) and evaluated the discrimination capability of the electronics. Then we have measured the imaging properties of the whole system in terms of Point Spread Function and using a home made thyroid phantom. We present also a comparison with a traditional gamma camera and an evaluation, made by both experimental measurements and software simulations, of the imaging characteristics related to the use of a collimation system. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 6 条
[1]   PERFORMANCE OF A NEW OHMIC CONTACT FOR GAAS PARTICLE DETECTORS [J].
ALIETTI, M ;
CANALI, C ;
CASTALDINI, A ;
CAVALLINI, A ;
CETRONIO, A ;
CHIOSSI, C ;
DAURIA, S ;
DELPAPA, C ;
LANZIERI, C ;
NAVA, F ;
VANNI, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (2-3) :344-348
[2]   GaAs detector optimization for different medical imaging applications [J].
Amendolia, SR ;
Bertolucci, E ;
Bisogni, MG ;
Bottigli, U ;
Ciocci, MA ;
Conti, M ;
Delogu, P ;
Fantacci, ME ;
Maestro, P ;
Marzulli, V ;
Pernigotti, E ;
Romeo, N ;
Rosso, V ;
Russo, P ;
Stefanini, A ;
Stumbo, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01) :14-17
[3]   Low contrast imaging with a GaAs pixel digital detector [J].
Amendolia, SR ;
Bisogni, MG ;
Bottigli, U ;
Ciocci, MA ;
Delogu, P ;
Dipasquale, G ;
Fantacci, ME ;
Giannelli, M ;
Maestro, P ;
Marzulli, VM ;
Pernigotti, E ;
Rosso, V ;
Stefanini, A ;
Stumbo, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1478-1482
[4]  
AMENDOLIA SR, 2001, 8 PIS M ADV DET MAY, V461, P422
[5]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[6]   Microscopic modelling of semi-insulating GaAs detectors [J].
Cola, A ;
Vasanelli, L ;
Reggiani, L ;
Cavallini, A ;
Nava, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01) :98-100