A magnetic resonance imaging-compatible, large-scale array for trans-skull ultrasound surgery and therapy

被引:71
作者
Clement, GT [1 ]
White, PJ [1 ]
King, RL [1 ]
McDannold, N [1 ]
Hynynen, K [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
关键词
phase aberration correction; thermal imaging; trans-skull therapy; ultrasound therapy;
D O I
10.7863/jum.2005.24.8.1117
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Objective. Advances in ultrasound transducer array and amplifier technologies have prompted many intriguing scientific proposals for ultrasound therapy. These include both mildly invasive and noninvasive techniques to be used in ultrasound brain surgery through the skull. In previous work, it was shown how a 500-element hemisphere-shaped transducer could correct the wave distortion caused by the skull with a transducer that operates at a frequency near 0.8 MHz. Because the objective for trans-skull focusing is its ultimate use in a clinical context, a new hemispheric phased-array system has now been developed with acoustic parameters that are optimized to match the values determined in preliminary studies. Methods. The transducer was tested by focusing ultrasound through ex vivo human skulls and into a brain phantom by means of a phase-adaptive focusing technique. Simultaneously, the procedure was monitored by the use of magnetic resonance guidance and thermometry. Results. The ultrasound focus of a 500-element 30-cm-diameter, 0.81-MHz array could be steered electronically through the skull over a volume of approximately 30 x 30 x 26 mm. Furthermore, temperature monitoring of the inner and outer surfaces of the skull showed that the array could coagulate targeted brain tissue without causing excessive skull heating. Conclusions. The successful outcome of these experiments indicates that intensities high enough to destroy brain tissue can be produced without excessive heating of the surrounding areas and without producing large magnetic resonance noise and artifacts.
引用
收藏
页码:1117 / 1125
页数:9
相关论文
共 14 条
[1]
Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[2]
Clement G, 2000, ULTRASON, P1243, DOI 10.1109/ULTSYM.2000.921548
[3]
Investigation of a large-area phased array for focused ultrasound surgery through the skull [J].
Clement, GT ;
White, J ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :1071-1083
[4]
A non-invasive method for focusing ultrasound through the human skull [J].
Clement, GT ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1219-1236
[5]
Micro-receiver guided transcranial beam steering [J].
Clement, GT ;
Hynynen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (04) :447-453
[6]
A hemisphere array for non-invasive ultrasound brain therapy and surgery [J].
Clement, GT ;
Sun, J ;
Giesecke, T ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3707-3719
[7]
FRY F J, 1977, Ultrasound in Medicine and Biology, V3, P179, DOI 10.1016/0301-5629(77)90069-2
[8]
FRY FJ, 1987, IEEE 1986 ULTR S P P
[9]
Thermal effects of focused ultrasound on the brain: Determination with MR imaging [J].
Hynynen, K ;
Vykhodtseva, NI ;
Chung, AH ;
Sorrentino, V ;
Colucci, V ;
Jolesz, FA .
RADIOLOGY, 1997, 204 (01) :247-253
[10]
Liquid or solid ultrasonically tissue-mimicking materials with very low scatter [J].
Madsen, EL ;
Frank, GR ;
Dong, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (04) :535-542