Control of interstitial thermal coagulation: Comparative evaluation of microwave and ultrasound applicators

被引:35
作者
Deardorff, DL [1 ]
Diederich, CJ [1 ]
Nau, WH [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Thermal Therapy Res Grp, San Francisco, CA 94143 USA
关键词
microwave; ultrasound; interstitial; thermal coagulation; thermal therapy;
D O I
10.1118/1.1334606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
This study presents a comparative evaluation of the control of heating and thermal coagulation with microwave (MW) and ultrasound (US) interstitial applicators. Helical coil MW antennas (17 mm and 25 mm length radiating antennae) were tested using an external implant catheter (2.2 mm o.d.) with water-cooling. US applicators with tubular transducers (2.2 and 2.5 mm o.d., 10 mm length, single-element and 3-element) were utilized with a direct-coupled configuration and internal water-cooling. Measurements of E-field distributions (for MW) and acoustic beam distributions (for US) were used to characterize the applicator energy output. Thermal performance was evaluated through multiple heating trials in vitro (bovine liver) and in vivo (porcine thigh muscle and liver) at varied levels of applied power (20-40 W for microwave, 15-35 W for ultrasound) and heating times (0.5-5 min). Axial temperature distributions in the tissue were recorded during heating, and dimensions of the resulting lesions of thermal coagulation were measured. Both MW and US applicators produced large volumes of tissue coagulation ranging from 8 to 20 cm(3) with singular heating times of 5 min. Radial depth of lesions for both MW and US applicators increased with heating duration and power levels, though US produced notably larger lesion diameters (30-42 mm for US vs 18-26 mm for MW. 5 min heating). Characteristic differences between the applicators were observed in axial energy distribution, tissue temperatures, and thermal lesion shapes. MW lesions increased significantly in axial dimensions (beyond the active applicator length) as applied power level and/or heating duration was increased, and lesion shapes were generally not uniform. US provided greater control and uniformity of heating, with energy deposition and axial extent of thermal lesions corresponding to the length of the active transducer(s). The improved ability to control the extent of thermal coagulation demonstrated by the US applicators provides greater potential to target a specific region of tissue. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:104 / 117
页数:14
相关论文
共 46 条
[1]
Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose [J].
Damianou, CA ;
Sanghvi, NT ;
Fry, FJ ;
MaassMoreno, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (01) :628-634
[2]
Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy [J].
Deardorff, DL ;
Diederich, CJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (10) :1356-1365
[3]
Angular directivity of thermal coagulation using air-cooled direct-coupled interstitial ultrasound applicators [J].
Deardorff, DL ;
Diederich, CJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (04) :609-622
[4]
Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation [J].
Deardorff, DL ;
Diederich, CJ ;
Nau, WH .
MEDICAL PHYSICS, 1998, 25 (12) :2400-2409
[5]
Deardorff DL, 1998, ULTRASON, P1541, DOI 10.1109/ULTSYM.1998.765237
[6]
Axial control of thermal coagulation using a multi-element interstitial ultrasound applicator with internal cooling [J].
Deardorff, DL ;
Diederich, CJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :170-178
[7]
Ultrasound applicators for interstitial thermal coagulation [J].
Diederich, CJ ;
Nau, WH ;
Stauffer, PR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) :1218-1228
[9]
Djavan B, 1998, Tech Urol, V4, P103
[10]
Sonographically guided microwave coagulation treatment of liver cancer: An experimental and clinical study [J].
Dong, BW ;
Liang, P ;
Yu, XL ;
Zeng, XQ ;
Wang, PJ ;
Su, L ;
Wang, XD ;
Xin, H ;
Li, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :449-454