Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy

被引:40
作者
Deardorff, DL [1 ]
Diederich, CJ [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, Thermal Therapy Res Grp, San Francisco, CA 94143 USA
关键词
interstitial ultrasound; thermal therapy; water-cooling;
D O I
10.1109/10.871409
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Internal water-cooling of direct-coupled ultrasound (US) applicators for interstitial thermal therapy (hyperthermia and coagulative thermal therapy) was investigated. Implantable applicators were constructed using tubular US sources (360 angular acoustic emittance, similar to 7 MHZ) Of 10 mm length and 1.5, 1.8, 2.2, and 2.5 mm outer diameter (OD), Directional applicators were also constructed using 2.2 mm OD tubes Sectored to provide active acoustic sectors of 90 degrees and 200 degrees. A water cooling mechanism was integrated within the inner lumen of the applicator to remove heat from the inner transducer surface. High levels of convective heat transfer (2100-3800 W/m(2)K) were measured for practical water flow rates of 20-80 mL/min, Comparative acoustic measurements demonstrated that internal water-cooling did not significantly degrade the acoustic intensity or beam distribution of the US transducers, Water-cooling allowed substantially higher levels of applied electrical power (>45 W) than previous designs (with air-cooling or no cooling), without detriment to the applicators. High-temperature heating trials performed with these applicators in vivo (porcine liver and thigh muscle) and in vitro (bovine liver) showed improved thermal penetration and coagulation, Radial depth of coagulation from the applicator surface ranged from 12 to 20 mm for 1-5 min of sonication with 28-W applied power. Higher powers (41 W) demonstrated increased coagulation depths (similar to 9 mm) at shorter times (15 s). Thermal lesion dimensions (angular and axial expanse) produced with directional applicators were controlled and directed, and corresponded to the active zone of the transducer, These characteristic lesion shapes were also generally unchanged with different sonication times and power, and were found to be consistent with previous coagulation studies using air cooled applicators. The implementation of water cooling is a significant advance for the application of ultrasound interstitial thermal therapy (USITT), providing greater treatment volumes, shorter treatment times, and the potential for treatment of highly perfused tissue with shaped lesions.
引用
收藏
页码:1356 / 1365
页数:10
相关论文
共 26 条
[1]   Angular directivity of thermal coagulation using air-cooled direct-coupled interstitial ultrasound applicators [J].
Deardorff, DL ;
Diederich, CJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (04) :609-622
[2]   Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation [J].
Deardorff, DL ;
Diederich, CJ ;
Nau, WH .
MEDICAL PHYSICS, 1998, 25 (12) :2400-2409
[3]   Ultrasound applicators for interstitial thermal coagulation [J].
Diederich, CJ ;
Nau, WH ;
Stauffer, PR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) :1218-1228
[4]   Ultrasound applicators with integrated catheter-cooling for interstitial hyperthermia: Theory and preliminary experiments [J].
Diederich, CJ .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (02) :279-297
[5]   Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: A feasibility study [J].
Diederich, CJ ;
Khalil, IS ;
Stauffer, PR ;
Sneed, PK ;
Phillips, TL .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (03) :401-419
[6]  
DIEDERICH CJ, 1999, P SPIE THERMAL TREAT, P178
[7]  
DIEDERICH CJ, 1996, IEEE ULTRASON S P, V2, P1303
[8]  
DIEDERICH CJ, 1997, P IEEE ULTR S TOR CA, P163
[9]   ACOUSTIC POWER CALIBRATIONS OF CYLINDRICAL INTRACAVITARY ULTRASOUND HYPERTHERMIA APPLICATORS [J].
HYNYNEN, K .
MEDICAL PHYSICS, 1993, 20 (01) :129-134
[10]   SMALL CYLINDRICAL ULTRASOUND SOURCES FOR INDUCTION OF HYPERTHERMIA VIA BODY CAVITIES OR INTERSTITIAL IMPLANTS [J].
HYNYNEN, K ;
DAVIS, KL .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1993, 9 (02) :263-274