A capillary mixer with adjustable reaction chamber volume for millisecond time-resolved studies by electrospray mass spectrometry

被引:111
作者
Wilson, DJ [1 ]
Konermann, L [1 ]
机构
[1] Univ Western Ontario, Dept Chem, London, ON N6A 5B7, Canada
关键词
D O I
10.1021/ac0346757
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel continuous-flow apparatus for on-fine kinetic studies of (bio)chemical solution-phase processes by electrospray ionization mass spectrometry (ESI-MS) is described. The device is based on two concentric capillaries. Fluid is released from the inner capillary into the intercapillary space, where it mixes with solution flowing through the outer capillary, thus initiating the reaction of interest. Gas-phase analyte ions are formed near the tip of the outer capillary by pneumatically assisted ESI. This setup allows the mixer to be placed directly within the ion source, thus providing a minimal dead volume of similar to8 nL. Time-resolved data can be recorded in both "spectral" and "kinetic" modes. In the former case, the position of the inner capillary is fixed at various points, such that entire mass spectra can be recorded for selected reaction times For experiments in kinetic mode, the mass spectrometer monitors the signal intensity at selected m/z values, while the inner capillary is continuously pulled back, thus providing intensity-time profiles for specific reactive species. A theoretical framework is developed that allows the measured kinetics to be analyzed by taking into account the effects of laminar flow within the reaction capillary. Failure to take these effects into account results in erroneous rate constants. Studies on the demetalation kinetics of chlorophyll reveal that the apparatus can reliably measure rate constants up to at least 100 s(-1). This represents a substantial improvement over previous ESI-MS-based kinetic methods. Spectral mode experiments on the refolding of ubiquitin show the changing proportions of denatured and tightly folded protein subpopulations in solution. When monitored in kinetic mode, the refolding process was found to proceed with a rate constant of 5.2 s(-1).
引用
收藏
页码:6408 / 6414
页数:7
相关论文
共 59 条
[1]  
Bakhtiar R, 1999, J PHYS ORG CHEM, V12, P511, DOI 10.1002/(SICI)1099-1395(199907)12:7<511::AID-POC160>3.0.CO
[2]  
2-S
[3]  
BEREZIN DB, 1976, RUSS J PHYS CHEM, V50, P720
[4]   UNFOLDING AND REFOLDING OCCUR MUCH FASTER FOR A PROLINE-FREE PROTEIN THAN FOR MOST PROLINE-CONTAINING PROTEINS [J].
BRANDTS, JF ;
BRENNAN, M ;
LIN, LN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1977, 74 (10) :4178-4181
[5]   Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry [J].
Brivio, M ;
Fokkens, RH ;
Verboom, W ;
Reinhoudt, DN ;
Tas, NR ;
Goedbloed, M ;
van den Berg, A .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3972-3976
[6]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[7]  
BURTSCHER B, 1997, BIOCHEMISTRY-US, V36, P6
[8]   PROBING CONFORMATIONAL-CHANGES IN PROTEINS BY MASS-SPECTROMETRY [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (24) :9012-9013
[9]   Diffusion measurements by electrospray mass spectrometry for studying solution-phase noncovalent interactions [J].
Clark, SM ;
Konermann, L .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (05) :430-441
[10]  
Eyles SJ, 1999, J MASS SPECTROM, V34, P1289, DOI 10.1002/(SICI)1096-9888(199912)34:12<1289::AID-JMS882>3.0.CO