Accuracy of 64-slice computed tomography for the preoperative detection of coronary artery disease in patients with chronic aortic regurgitation

被引:61
作者
Scheffel, Hans
Leschka, Sebastian
Plass, Andr
Vachenauer, Robert
Gaemperli, Oliver
Garzoli, Elisabeth
Genoni, Michele
Marincek, Borut
Kaufmann, Philipp
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Univ Zurich, Ctr Intergrat Human Physiol, Zurich, Switzerland
关键词
D O I
10.1016/j.amjcard.2007.03.087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We studied the diagnostic accuracy of 64-slice computed tomography for the diagnosis of significant coronary artery disease (CAD) compared with conventional coronary angiography (CA) in patients with chronic aortic regurgitation (AR) referred for elective aortic valve surgery. Fifty consecutive patients with chronic AR (38 men, mean age 54 +/- 14 years) scheduled for valve surgery underwent 64-slice computed tomographic (CT) coronary angiography and CA. Significant stenosis was defined as a luminal diameter decrease > 50%. Mean heart rate during CT scanning was 65.5 +/- 7.4 beats/min. Mean Agatston score was 136 278 (range 0 to 1207); prevalence of significant CAD in the study population was 26% (13 of 50 patients). Thirteen of 742 segments (1.8%) in 3 patients were considered nondiagnostic with computed tomography because of motion artifacts (n = 9) or calcium (n = 4). In a patient-based analysis taking nonevaluative segments as falsely positive, sensitivity, specificity, and positive and negative predictive values of computed tomography were 100%, 95%, 87%, and 100%, respectively. Preoperative CA could have been avoided in 70% of patients (35 of 50), CA would have been performed to confirm the CT diagnosis in 26% (13 of 50), and unnecessary CA would have been performed in 4% (2 of 50) on the basis of false-positive CT ratings. In conclusion, 64-slice CT coronary angiography provides high diagnostic accuracy for diagnosing significant CAD in patients with chronic AR and may be used as a filter test before valve surgery to decide whether CA should be performed. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:701 / 706
页数:6
相关论文
共 19 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Aortic stenosis: Comparative evaluation of 16-detector row CT and echocardiography [J].
Alkadhi, H ;
Wildermuth, S ;
Plass, A ;
Bettex, D ;
Baumert, B ;
Leschka, S ;
Desbiolles, LM ;
Marincek, B ;
Boehm, T .
RADIOLOGY, 2006, 240 (01) :47-55
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   PROGNOSTIC VALUE OF A CORONARY-ARTERY JEOPARDY SCORE [J].
CALIFF, RM ;
PHILLIPS, HR ;
HINDMAN, MC ;
MARK, DB ;
LEE, KL ;
BEHAR, VS ;
JOHNSON, RA ;
PRYOR, DB ;
ROSATI, RA ;
WAGNER, GS ;
HARRELL, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (05) :1055-1063
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[7]   Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis [J].
Gilard, M ;
Cornily, JC ;
Pennec, PY ;
Joret, C ;
Le Gal, G ;
Mansourati, J ;
Blanc, JJ ;
Boschat, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) :2020-2024
[8]   PREVALENCE OF ANGINA-PECTORIS AND ABNORMAL CORONARY ARTERIOGRAMS IN SEVERE AORTIC VALVULAR DISEASE [J].
GRABOYS, TB ;
COHN, PF .
AMERICAN HEART JOURNAL, 1977, 93 (06) :683-686
[9]   Coronary multidetector computed tomography - A new standard for preoperative risk assessment? [J].
Hoffmann, U ;
Shapiro, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) :2025-2026
[10]   Eight-row multidetector computed tomography coronary angiography evaluation of significant coronary artery disease in patients with severe aortic valve stenosis [J].
Holmstrom, Miia ;
Sillanpaa, Mikko A. ;
Kupari, Markku ;
Kivisto, Sari ;
Lauerma, Kirsi .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (05) :703-710