Determination of cyanide using a microbial sensor

被引:22
作者
Nakanishi, K [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
关键词
Saccharomyces cerevisiae; microbial biosensor; immobilized cell; cyanide determination; respiration inhibition; ELECTRODE;
D O I
10.1007/BF02788064
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A microbial cyanide sensor was prepared, consisting of immobilized Saccharomyces cerevisiae and an oxygen electrode. When the electrode was inserted into a solution containing glucose, the respiration activity of the microorganisms increased. The change in the respiration activity is monitored with the oxygen electrode. When cyanide is added to the sample solution, the electron transport chain reaction of the respiration system in the mitochondria is inhibited, resulting in a decrease in respiration. The inhibition is caused by cyanide binding with respiration enzymes such as the cytochrome oxidase complex in the mitochondrial inner membrane. Therefore, the cyanide concentration can be measured from the change in the respiration rate. When the sensor was applied to a batch system at pH 8.0 and 30 degrees C, the cyanide calibration curve showed linearity in the concentration range between 0.3 mu M and 150 mu M CN-.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 13 条
[1]   ENZYME METHOD FOR THE SPECTROPHOTOMETRIC DETERMINATION OF MICRO-AMOUNTS OF CYANIDE [J].
FONONG, T .
ANALYST, 1987, 112 (07) :1033-1035
[2]  
Franson M.A., 1980, Standard methods for examination of water and wastewater, V15th
[3]   ELECTRODE INDICATOR TECHNIQUE FOR MEASURING LOW-LEVELS OF CYANIDE [J].
FRANT, MS ;
ROSS, JW ;
RISEMAN, JH .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2227-&
[4]   A FLOW THROUGH ANALYSIS BIOSENSOR SYSTEM FOR CYANIDE [J].
GROOM, CA ;
LUONG, JHT .
JOURNAL OF BIOTECHNOLOGY, 1991, 21 (1-2) :161-172
[5]   AMPEROMETRIC ESTIMATION OF BOD BY USING LIVING IMMOBILIZED YEASTS [J].
HIKUMA, M ;
SUZUKI, H ;
YASUDA, T ;
KARUBE, I ;
SUZUKI, S .
EUROPEAN JOURNAL OF APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1979, 8 (04) :289-297
[6]   MICROBIAL ELECTRODE BOD SENSORS [J].
KARUBE, I ;
MATSUNAGA, T ;
MITSUDA, S ;
SUZUKI, S .
BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (10) :1535-1547
[7]  
KARUBE I, 1990, BIOSENSORS PRACTICAL, P155
[8]  
KARUBE I, 1993, CURRENT OPINION BIOT, V5, P54
[9]  
KARUBE I, 1994, IEEE ENG MED BIOL, P365
[10]   APPLICATION OF CYANIDE-METABOLIZING ENZYMES TO ENVIRONMENTAL-CONTROL - ENZYME THERMISTOR ASSAY OF CYANIDE USING IMMOBILIZED RHODANESE AND INJECTASE [J].
MATTIASSON, B ;
MOSBACH, K ;
SVENSON, A .
BIOTECHNOLOGY AND BIOENGINEERING, 1977, 19 (11) :1643-1651