A FLOW THROUGH ANALYSIS BIOSENSOR SYSTEM FOR CYANIDE

被引:15
作者
GROOM, CA [1 ]
LUONG, JHT [1 ]
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL H4P 2R2,QUEBEC,CANADA
关键词
BIOSENSOR; RHODANESE; SULFITE OXIDASE; CYANIDE; AMPEROMETRIC;
D O I
10.1016/0168-1656(91)90268-Z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A flow through biosensor system has been developed for the determination of free cyanide in brass plating and rinsing solutions. The system consisted of rhodanese immobilized on aminopropyl glass beads via glutaraldehyde activation to form an enzyme column and sulfite oxidase immobilized on a preactivated nylon membrane and attached to the surface of a hydrogen peroxide electrode (platinum vs silver/silver chloride at 0.7 V). The immobilized rhodanese first converted cyanide to thiocyanate in the presence of thiosulfate and produced sulfite which was, in turn, converted to sulfate by immobilized sulfate oxidase. The latter enzymatic reaction also released hydrogen peroxide which was amperometrically detected at the platinum anode. The biosensor system exhibited a linear response from 5 to 1000-mu-M cyanide and could be reused for 35 repeated analyses. The system was stable for at least 18 h of continuous operation at 25-degrees-C. The immobilized rhodanese and sulfite oxidase stored in 3 M ammonium sulfate were stable for 4 months at -20-degrees-C and 50 days at 4-degrees-C, respectively. When measuring cyanide in metal plating solutions, the results obtained by the biosensor system agreed well with that of soluble enzymatic and the colorimetric assays. The data obtained, however, was not in agreement to those of the commercially available Orion cyanide electrode.
引用
收藏
页码:161 / 172
页数:12
相关论文
共 17 条
[1]   THE DETERMINATION OF TOTAL SERUM-CHOLESTEROL BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION [J].
CARPENTER, A ;
PURDY, WC .
ANALYTICAL LETTERS, 1990, 23 (03) :425-435
[2]  
COHEN HJ, 1971, J BIOL CHEM, V246, P359
[3]  
FENONG T, 1987, ANALYST, V112, P1033
[4]  
FRANSON MA, 1980, STANDARD METHODS EXA, P312
[5]   ELECTRODE INDICATOR TECHNIQUE FOR MEASURING LOW-LEVELS OF CYANIDE [J].
FRANT, MS ;
ROSS, JW ;
RISEMAN, JH .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2227-&
[6]  
FRANT MS, 1971, PLATING, V58, P686
[7]  
Guilbault GG, 1985, IMMOBILISED CELLS EN, P55
[8]  
JENKS WR, 1978, ENCY CHEM TECHNOLOGY, V7, P314
[9]   PRIMARY STRUCTURE OF AVIAN HEPATIC RHODANESE [J].
KOHANSKI, RA ;
HEINRIKSON, RL .
JOURNAL OF PROTEIN CHEMISTRY, 1990, 9 (04) :369-377
[10]   DEVELOPMENTS AND APPLICATIONS OF BIOSENSORS [J].
LUONG, JHT ;
MULCHANDANI, A ;
GUILBAULT, GG .
TRENDS IN BIOTECHNOLOGY, 1988, 6 (12) :310-316