Evaluation of the retention dependence on the physicochemical properties of solutes in reversed-phase liquid chromatographic linear gradient elution based on linear solvation energy relationships

被引:38
作者
Li, JW [1 ]
Cai, B [1 ]
机构
[1] 3M Ctr, 3M Pharmaceut, Analyt Res & Dev, St Paul, MN 55144 USA
关键词
linear solvation energy relationships; gradient elution; mobile phase composition; retention prediction; column characterization;
D O I
10.1016/S0378-4347(00)00527-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the results of the evaluation of retention dependence on the physicochemical properties of solutes in linear gradient elution by reversed-phase liquid chromatography (RPLC) based on linear solvation energy relationships (LSERs). Retention time data on Inertsil ODS(3) column by linear gradient elution were collected for both acetonitrile-water and methanol-water binary mobile phases under various gradient steepness. Based on the LSERs, the retention times were linearly correlated with the physicochemical properties (size, dipolarity, and hydrogen bond donor-acceptor acidity and basicity) of solutes. As predicted by LSERs, very acceptable linear relationships are observed for both mobile phases. While the magnitudes of the coefficients are modified by the gradient steepness, their signs are consistent with those obtained by isocratic elution. As obtained for isocratic elution, the dominant factors to retention in linear gradient elution of RPLC are the solutes' size and hydrogen bond acceptor basicity. The conclusions of the study allow us to predict retention in chromatographic method development by gradient elution. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 36 条
[21]  
PARK JH, 1994, J CHROMATOGR A, V664, P149
[22]   INTERPRETATION OF NORMAL-PHASE SOLVENT STRENGTH SCALES BASED ON LINEAR SOLVATION ENERGY RELATIONSHIPS USING THE SOLVATOCHROMIC PARAMETER-PI-STAR, PARAMETER-ALPHA AND PARAMETER-BETA [J].
PARK, JH ;
CARR, PW .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (02) :123-136
[23]   Determination of solute descriptors of tripeptide derivatives based on high-throughput gradient high-performance liquid chromatography retention data [J].
Plass, M ;
Valko, K ;
Abraham, MH .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :51-60
[24]   STUDY OF RETENTION PROCESSES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY THE USE OF THE SOLVATOCHROMIC COMPARISON METHOD [J].
SADEK, PC ;
CARR, PW ;
DOHERTY, RM ;
KAMLET, MJ ;
TAFT, RW ;
ABRAHAM, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2971-2978
[25]   Characterization of different RP-HPLC columns by a gradient elution technique [J].
Sandi, A ;
Bede, A ;
Szepesy, L ;
Rippel, G .
CHROMATOGRAPHIA, 1997, 45 (1) :206-214
[26]  
SEIBERT DS, 1995, CHROMATOGRAPHIA, V41, P51, DOI 10.1007/BF02688000
[27]  
Snyder LR, 1998, ADV CHROMATOGR, V38, P115
[28]   Study of retention in reversed-phase liquid chromatography using linear solvation energy relationships - II. The mobile phase [J].
Tan, LC ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :1-19
[29]   Study of retention in reversed-phase liquid chromatography using linear solvation energy relationships .1. The stationary phase [J].
Tan, LC ;
Carr, PW ;
Abraham, MH .
JOURNAL OF CHROMATOGRAPHY A, 1996, 752 (1-2) :1-18
[30]   Relationships between the chromatographic hydrophobicity indices and solute descriptors obtained by using several reversed-phase, diol, nitrile, cyclodextrin and immobilised artificial membrane-bonded high-performance liquid chromatography columns [J].
Valkó, K ;
Plass, M ;
Bevan, C ;
Reynolds, D ;
Abraham, MH .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :41-55