Detection of TP53 mutation using a portable surface plasmon resonance DNA-based biosensor

被引:76
作者
Jiang, TS
Minunni, M
Wilson, P
Zhang, J
Turner, APF
Mascini, M
机构
[1] Univ Florence, Dipartimento Chim, I-50019 Sesto Fiorentino, Italy
[2] Hunan Normal Univ, Life Sci Coll, Changsha 410081, Hunan, Peoples R China
[3] Cranfield Univ, Silsoe MK45 4DT, Beds, England
关键词
SPR; DNA biosensor; TP53; mutation; Spreeta (TM);
D O I
10.1016/j.bios.2004.08.040
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A DNA-based surface plasmon resonance (SPR) biosensor has been developed for the detection of TP53 mutation using the inexpensive and commercially available instrument, SPREETA (TM) SPR-EVM-BT, from Texas Instruments. A direct immobilisation procedure, based on the coupling of thiol-derivatised oligonucleotide probes (Probe-C6-SH) to bare gold sensor surfaces, was optimized using synthetic oligonucleotides. Hybridisation reactions between the immobilised probe and a short sequence (26 mer) complementary, non-complementary and one-point mutation DNA were then investigated. The main analytical parameters of the sensor system were studied in detail including selectivity, sensitivity, reproducibility and analysis time. Finally, the sensor system was successfully applied to polymerase chain reaction (PCR)-amplified real samples, DNA extracted from both normal, wild-type, (Jurkat) and mutated (Molt 4), carrying the mutation at codon 248 of the TP53 cell lines. The results obtained demonstrate that the DNA-based SPR biosensor was able to distinguish sequences present in the various samples that differ only by one base; and hence, it appears to be a strong candidate technique for the detection of gene mutation. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1939 / 1945
页数:7
相关论文
共 21 条
[1]   Combination of amplification and post-amplification strategies to improve optical DNA sensing [J].
Giakoumaki, E ;
Minunni, M ;
Tombelli, S ;
Tothill, IE ;
Mascini, M ;
Bogani, P ;
Buiatti, M .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (04) :337-344
[2]   Mutation analysis of p53 in ovarian rumors by DHPLC [J].
Gross, E ;
Kiechle, M ;
Arnold, N .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 47 (1-2) :73-81
[3]   Towards fast and inexpensive molecular diagnostic: the case of TP53 [J].
Jiang, TS ;
Minunni, M ;
Mascini, M .
CLINICA CHIMICA ACTA, 2004, 343 (1-2) :45-60
[4]   Surface plasmon resonance biosensor for genetically modified organisms detection [J].
Mariotti, E ;
Minunni, M ;
Mascini, M .
ANALYTICA CHIMICA ACTA, 2002, 453 (02) :165-172
[5]   Biosensors as new analytical tool for detection of Genetically Modified Organisms (GMOs) [J].
Minunni, M ;
Tombelli, S ;
Mariotti, E ;
Mascini, M ;
Mascini, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :589-593
[6]   Electrochemical analysis of single nucleotide polymorphisms of p53 gene [J].
Miyahara, H ;
Yamashita, K ;
Kanai, M ;
Uchida, K ;
Takagi, M ;
Kondo, H ;
Takenaka, S .
TALANTA, 2002, 56 (05) :829-835
[7]   Relative quantitation of p53 and MDM2 gene expression in leiomyosarcoma; real-time semi-quantitative reverse transcription-polymerase chain reaction [J].
Miyajima, K ;
Tamiya, S ;
Oda, Y ;
Adachi, T ;
Konomoto, T ;
Toyoshiba, H ;
Masuda, K ;
Tsuneyoshi, M .
CANCER LETTERS, 2001, 164 (02) :177-188
[8]   Site-directed mutagenesis of exon 5 of p53:: Purification, analysis, and validation of amplicons for DHPLC [J].
Narayanaswami, G ;
Taylor, PD .
GENETIC TESTING, 2002, 6 (03) :177-184
[9]  
Nilsson P, 1997, J MOL RECOGNIT, V10, P7, DOI 10.1002/(SICI)1099-1352(199701/02)10:1<7::AID-JMR341>3.0.CO
[10]  
2-9